Daikin FTX20KV1B Operation Manual

Daikin FTX20KV1B Operation Manual

Room air conditioner
Hide thumbs Also See for FTX20KV1B:

Advertisement

DAIKIN ROOM AIR CONDITIONER

OPERATION MANUAL

Enjoy year-round comfort.
MODELS
FTX20KV1B
FTX25KV1B
FTX35KV1B
FTX50KV1B
FTX60KV1B

Advertisement

Table of Contents
loading

Summary of Contents for Daikin FTX20KV1B

  • Page 1: Operation Manual

    DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL Enjoy year-round comfort. MODELS FTX20KV1B FTX25KV1B FTX35KV1B FTX50KV1B FTX60KV1B...
  • Page 2: Comfort Airflow

    Features Enhanced comfort and energy savings COMFORT AIRFLOW The airflow direction is upward while in COOL operation, and downward while in HEAT operation. This function prevents cold or warm air from blowing directly on your body. Page 15 ECONO This function enables efficient operation by limiting the maximum power consumption.
  • Page 3: Table Of Contents

    Contents „ Read Before Operation Safety Precautions  .........  Names of Parts  ......  FTX20KV1B / FTX25KV1B / FTX35KV1B Names of Parts  ..........  FTX50KV1B / FTX60KV1B Preparation Before Operation  ......   „ Basic Operation AUTO · COOL · DRY · HEAT · FAN ONLY Operation .........
  • Page 4: Read Before Operation

    Read Before Operation Safety Precautions • Keep this manual where the user can easily find it. • Read the precautions in this manual carefully before operating the unit. • This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • Page 5 Read Before Operation Safety Precautions • Do not place objects that are susceptible to moisture directly beneath the indoor or outdoor units. Under certain conditions, condensation on the main unit or refrigerant pipes, air filter dirt or drain blockage may cause dripping, resulting in fouling or failure of the object concerned.
  • Page 6: Names Of Parts

    Read Before Operation Names of Parts FTX20KV1B / FTX25KV1B / FTX35KV1B Indoor Unit Air inlet Front panel Air outlet Flap (horizontal blade) Model name plate Indoor temperature Page 14 sensor • Detects the air temperature Louvers (vertical blades) around the unit.
  • Page 7: Names Of Parts

    Read Before Operation Names of Parts FTX20KV1B / FTX25KV1B / FTX35KV1B „ Open the front panel Titanium apatite photocatalytic air-purifying filter (without frame) Air filter Outdoor Unit • The appearance of the outdoor unit may differ between different models. Air inlet...
  • Page 8: Ftx50Kv1B / Ftx60Kv1B

    Read Before Operation Names of Parts FTX50KV1B / FTX60KV1B Indoor Unit Air inlet Front panel Air outlet Flaps (horizontal blades) Page Model name plate Louvers (vertical blades) Indoor temperature sensor • The louvers are inside of the air • Detects the air temperature around the unit.
  • Page 9 Read Before Operation Names of Parts FTX50KV1B / FTX60KV1B „ Open the front panel Air filter Titanium apatite photocatalytic air-purifying filter (with frame) Outdoor Unit • The appearance of the outdoor unit may differ between different models. Air inlet Outdoor temperature sensor (back) (back and side) Refrigerant piping and inter-...
  • Page 10 Read Before Operation Names of Parts Remote Controller Display (LCD) Signal transmitter • Displays the current settings. (In this illustration, each section is shown with its displays on for the purpose of explanation.) Receiver AUTO button • To use the remote controller, aim the •...
  • Page 11: Preparation Before Operation

    Read Before Operation Preparation Before Operation To insert the batteries Remove the back cover by sliding and then slightly lifting it. Insert 2 dry batteries AAA.LR03 (alkaline). Replace the back cover. Position correctly! To fix the remote controller holder to a wall Remote controller Choose a place where the signals reach the unit.
  • Page 12: Basic Operation

    Basic Operation AUTO · COOL · DRY · HEAT · FAN ONLY Operation The air conditioner operates with the operation mode of your choice. To start operation AUTO operation • To automatically select an appropriate temperature and operation mode. Press COOL operation •...
  • Page 13: Tips For Saving Energy

    Basic Operation AUTO · COOL · DRY · HEAT · FAN ONLY Operation To stop operation Press • The OPERATION lamp goes off. To change the temperature setting Press • Press to raise the temperature and press to lower the temperature. COOL operation HEAT operation AUTO operation...
  • Page 14: Adjusting The Airflow Rate

    Basic Operation Adjusting the Airflow Rate You can adjust the airflow rate to increase your comfort. To adjust the airflow rate setting Press • Each pressing of changes the airflow rate setting in sequence. AUTO Indoor unit quiet Airflow rate 1-5 (Low to High) •...
  • Page 15: Adjusting The Airflow Direction

    • “ ” disappears from the LCD. To adjust the louvers at desired position Hold the knobs and move the louvers (vertical blades). FTX20KV1B / FTX25KV1B / FTX50KV1B / FTX60KV1B FTX35KV1B Knobs Knobs Knobs...
  • Page 16: Useful Functions

    Useful Functions COMFORT AIRFLOW Operation The air direction and flow rate are adjusted so that the air will not blow directly at people in the room. To start COMFORT AIRFLOW operation Press • “ ” is displayed on the LCD. COOL and DRY operation HEAT operation Flap direction...
  • Page 17: Econo Operation

    Useful Functions ECONO Operation ECONO operation enables efficient operation by limiting the maximum power consumption. This function is useful to prevent the circuit breaker from tripping when the unit operates alongside other appliances on the same circuit. To start ECONO operation Press •...
  • Page 18: Timer Operation

    TIMER Operation ON/OFF TIMER Operation Timer functions are useful for automatically switching the air conditioner on or off at night or in the morning. You can also use the ON TIMER and OFF TIMER together. To use ON TIMER operation Press “...
  • Page 19 TIMER Operation ON/OFF TIMER Operation To use OFF TIMER operation Press “ ” is displayed on the LCD. • Each pressing of advances the time setting by 1 hour. The time can be set between 1 and 12 hours. • The TIMER lamp lights orange. Display To cancel OFF TIMER operation Press...
  • Page 20: Care

    Care Care and Cleaning FTX20KV1B / FTX25KV1B / FTX35KV1B CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury.
  • Page 21: Care And Cleaning

    Care Care and Cleaning FTX20KV1B / FTX25KV1B / FTX35KV1B „ Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. • It is recommended to clean the air filters every 2 weeks.
  • Page 22: Care And Cleaning

    Care Care and Cleaning FTX20KV1B / FTX25KV1B / FTX35KV1B „ Titanium apatite photocatalytic air-purifying filter [Replacement] Open the front panel and Remove the filter from the tabs pull out the air filters. Page 20 and prepare a new one. Take off the titanium apatite photocatalytic air-purifying filters.
  • Page 23 Care Care and Cleaning FTX50KV1B / FTX60KV1B CAUTION • Before cleaning, be sure to stop the operation and turn off the circuit breaker. • Do not touch the aluminium fins of the indoor unit. If you touch those parts, this may cause an injury. „...
  • Page 24: Air Filter

    Care Care and Cleaning FTX50KV1B / FTX60KV1B „ Air filter Open the front panel. Wash the air filters with water or clean them with • Hold the front panel by the sides and open it. vacuum cleaner. • It is recommended to clean the air filters every 2 weeks.
  • Page 25 Care Care and Cleaning FTX50KV1B / FTX60KV1B „ Titanium apatite photocatalytic air-purifying filter [Replacement] Open the front panel and Remove the filter from the filter pull out the air filters. Page 23 frame and prepare a new one. • Do not throw away the filter frame. Reuse the filter Take off the titanium apatite frame when replacing the titanium apatite photocatalytic air-purifying filter.
  • Page 26: All Models

    Care Care and Cleaning All models „ Prior to a long period of non-use Operate the FAN ONLY mode for several hours to dry out the inside. • Press After operation stops, turn off the circuit breaker for the room air conditioner.
  • Page 27: When The Need Arises

    When the Need Arises Indoor unit The flap does not start swinging immediately. • The air conditioner is adjusting the position of the flap. The flap will start moving soon. The air conditioner stops generating Different sounds are heard. airflow during HEAT operation. „...
  • Page 28: Troubleshooting

    When the Need Arises Troubleshooting Before making an inquiry or a request for repair, please check the following. If the problem persists, consult your dealer. Not a problem Check This case is not a problem. Please check again before requesting repairs.
  • Page 29: Remote Controller

    When the Need Arises Troubleshooting Mist comes out Case Description / what to check • This happens when the air in the room is cooled into mist by the cold airflow during COOL Mist comes out of the indoor unit. or other operation.
  • Page 30: Call The Service Shop Immediately

    When the Need Arises Troubleshooting „ Call the service shop immediately WARNING When an abnormality (such as a burning smell) occurs, stop operation and turn off the circuit breaker. • Continued operation in an abnormal condition may result in troubles, electric shocks or fire. •...
  • Page 31 When the Need Arises Troubleshooting „ Fault diagnosis by remote controller • The remote controller can receive relevant error codes from the indoor unit. When is held down for about 5 seconds, “ ” blinks in the temperature display section. Press repeatedly until a continuous beep is produced.
  • Page 32 3P393186-1C 2015.02...

Table of Contents