• Ceiling Plate may vary in size depending on ceiling angle. Please specify ceiling pitch prior to ordering the ceiling plate. • Heat & Glo Curve 100 wood burner’s are tested and approved to the N.Z. National Environmental Stan- dards;...
Curve 100 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
Curve 100 Technical Data A. INSTALLATION The house owner is responsible for ensuring that all neces- sary national and local safety measures are observed during installation and fitting and also responsible for observing the fitting and operating instructions detailed in this manual.
Curve 100 Installation & Assembly A. POSITIONING YOUR WOOD BURNING STOVE D. LEVELING THE UNIT The wood burning stove must be set up so the stove, flue Four leveling bolts have come installed on the unit. connection, flue pipe, and chimney system can be cleaned Following installation, adjustments can be made to the and serviced.
B. FLOOR PROTECTOR ▪ If installed directly onto a concrete slab, the concrete slab Heat & Glo Curve 100 does not require a insulating Floor can be considered as the floor protector,but must maintain Protector, as they are tested and comply with the minimum the minimum measurement listed.
Page 8
Curve 100 Fig. 4 CORNER POSITIONING (45°) FLOOR PROTECTOR Table 2 DESCRIPTION With Double Pioneer Double Flue Mounted Shield Universal Flue Shield Shall be Fitted Fitted Min. clearance from firebox corner to corner walls Min. distance from center of spigot to corner walls Min.
Operation A, GENERAL USE D. FUELS The Curve 100 Wood Stove is designed and tested for intermittent The Curve 100 wood stove is designed to burn a wide use. This means that it is not designed for or recommended to range of firewood species.
Curve 100 E. PRIMARY AIR 01 Proper Fill and Startup Configuration 01 Proper Fill and Startup Configuration (Lower Air Control) (Fig. 2) 01 Proper Fill and Startup Configuration The primary air is controlled by the lever on the left side of the appliance.
Curve 100 G. SECONDARY AIR J. FRONT DOOR SEAL This unit is equipped with a secondary combustion system The front door has a non-combustible rope which creates that cannot be regulated. The purpose of this secondary a tight seal for the firebox. The first time you open the...
Curve 100 Chimney Systems A. GENERAL INSTRUCTIONS FOR FLUE SYSTEM 10. Install the flue pipes by preferred method – either up or ▪ Flue pipe installed crimp/narrow end down down the outer casing. Affix each length per the notes in ▪...
Page 13
12.5 V ented Ceiling Plate Pioneer Double Flue Shield Flue Pipe Heat & Glo Curve 100 Floor Protector The flue crimp must be cut so the swage (half-moon bulge after the crimp) fits tightly into the spigot. 5/2013 Heat & Glo •...
Page 14
3 x Ø flue pipe Curve 100 Ceiling flue pipe Ø FLUE PENETRATION Fig. 8 1.QF.1F Fig. 9 FLUE PENETRATION FLUE PENETRATION Un-tested flue systems, as per AS/NZS 2918:2001, 4.6.3 (b) n-tested flue systems, as per AS/NZS 2918:2001, 4.6.3(b) ...
Curve 100 Maintenance A. ASH DRAWER (Fig. 4) B. REFRACTORY Before attempting any maintenance on the unit ensure that The firebox is lined with molded refractory firebrick. The the unit is cold and has no embers in the firebox. To access refractory protects the outside of the appliance and retains the ash drawer open the glass front.
Curve 100 Troubleshooting Smoke escaping Poor heating performance of stove • Damp wood • Damp wood • Chimney not drawing properly • Not enough wood • Chimney is not properly dimensioned for the stove • Inferior wood quality with low fuel value •...
Curve 100 Reference Materials A. AS/NZS 2918:2001 General Notes WARNINGS: WARNING: THE APPLIANCE AND FLUE SYSTEM SHALL BE INSTALLED IN ACCORDANCE WITH AS/NZS 2918 AND THE APPROPRIATE REQUIREMENTS OF THE RELEVANT BUILDING CODE OR CODES. WARNING: APPLIANCES INSTALLED IN ACCORDANCE WITH THIS STANDARD SHALL COMPLY WITH THE REQUIREMENTS OF AS/NZS 4013 WHERE REQUIRED BY THE REGULA- TORY AUTHORITY, I.E.
Curve 100 AUSTRALIAN WARRANTY INFORMATION Hearth & Home Technologies Inc (HHT) 1445 N. Highway | Colville, WA 99114 | (509-684-3745) HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.
Page 19
Curve 100 OTHER RIGHTS The HHT manufacturer’s warranty is in addition to other rights and remedies that you may have under Australian law. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage.
CONTACT INFORMATION: Heat & Glo, a brand of Hearth & Home Technologies Inc. 20802 Kensington Boulevard, Lakeville, MN 55044 www.heatnglo.com We recommend that you record the following pertinent information for your Curve 100 Date purchased/installed: Serial Number: Location on appliance:...
Need help?
Do you have a question about the CURVE 100 and is the answer not in the manual?