8. Pressure switch is defective (very rare).
8.3.2 H Code
STOVE STOPS FEEDING PELLETS AND
BEFORE RESETTING TAKE CARE IN READING THE POSSIBLE CAUSES AND THEN
PRESS ON
Possible Cause:
1. Inadequate fuel is used.
2. The flue is not properly installed.
3. The flue is blocked or needs cleaning.
54
AND
AT THE SAME TIME FOR 2 SECONDS.
check fuse F4 and F5 on the control board. A
defective fuse will be darkened or will have a
broken filament. If the fuses are good, the
combustion or exhaust blower is probably
defective. Replace the faulty part.
Even though this situation is highly unlikely,
it's possible the pressure switch is defective.
To test the airflow pressure switch, you need
to disconnect the air hose from the blower
casing. With the other end still attached to the
switch, very gently suck on the loose end of
the hose (you may want to completely
disconnect the hose from the stove and the
switch first and make sure it is clear). If you
hear a « click », the switch is working. Be
careful: too much suction can damage the
switch.
APPEARS ON THE CONTROL BOARD.
Possible Remedy:
Remove the burn pot, make sure that all
openings are clear and check that no ash has
filled the tube around the igniter. Refer to the
maintenance section. Also, make sure that
the recommended fuel is used (see Section
4.8.1: Proper Fuel).
Make sure the venting system meets the
criteria in the Section 4: Venting System as
well as the venting system manufacturer's
instructions.
One
of
the
following
obstructed or blocked; air intake shutter,
combustion
blower,
exchangers and channels, exhaust blower
and or venting system. Refer to Section 7:
Maintenance.
components
is
burn
pot,
heat