Automatic Offset Control (Aoc); No Clean Mode - Dalstar DS-44-04M30 User's Manual And Reference

4m30 series 30 fps 2k x 2k
Table of Contents

Advertisement

4M30 Camera User's Manual
The read user offset commands allow the user to read back this information from the
camera.
Reading Channel 4 Offset from the Camera
To read Channel 4 offset setting from the camera, use these commands:
Binary
Hex

3.11 Automatic Offset Control (AOC)

The AOC defines the digitized value of black for the camera. An ideal camera (no dark
current, no shot noise, etc.) in total darkness produces an image with all pixels equal to
the AOC set point value. This command allows you to control the AOC set point of the
ADC video board. The four ADC video boards in the 4M30 can each be controlled
independently. Normally all channels are controlled with the same set point value. The
default value is 50 DNs, or counts.
Example: Set the Channel 2 AOC Set Point to 32 DNs
Binary
Hex

3.12 No Clean Mode

There is no way to prevent the CCD imager from integrating (accumulating charge due to
light falling on the imager). Under some conditions this will cause the image to show
smearing in the vertical direction, and increase Dark Current. In order to reduce this
effect, the 4M30 camera runs horizontal and vertical clocks during idle time to flush the
charge. Under some conditions, this feature may be undesirable. For example, when
wanting to synchronize camera integration to an external event in the External
Integration Mode. Under these conditions, the user can enable the No Clean Mode by
setting bit [2] in the Control Register = 1. No Clean Mode can only be enabled when in
Programmed Integration Mode (bit [7] of the Control Register =1)
DALSA
Read MSB
0111 0011
73h
Value
= 32
= 20h
Command
0001 1000
18h
Read LSB
0111 0010
72h
Value
0010 0000
20
25
03-32-10030-03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dalstar ds-46-04m30

Table of Contents