Dalstar DS-44-04M30 User's Manual And Reference page 19

4m30 series 30 fps 2k x 2k
Table of Contents

Advertisement

4M30 Camera User's Manual
WARNING:
!
addresses may overwrite camera calibration information, requiring the camera to be
returned for recalibration.
WARNING:
sent to the camera for a minimum of 1 second after power up.
DALSA
Each set of commands includes read and write variants. With the exception of reset
commands, all 8-bit write commands must be followed by an 8-bit data byte. The
commands are interpreted as follows:
Table 12: ADC Bit Definitions
Bit
Function
0:3
Command Register Address (Reference
Table 12)
4:5
ADC Board Address
00 = ADC Channel 1
01 = ADC Channel 2
10 = ADC Channel 3
11 = ADC Channel 4
6
Command Type
0 = Write
1 = Read
7
Board Type
0 = ADC Board
1 = Clock Board
Any commands not listed in this manual should be considered invalid to the 4M30
user.
A number of functions and modes depend on the ADC/Control Register settings.
These settings are detailed in the following sections.
The "Write Control Register" command is used to write data that controls specific
camera triggering and test functions. This command must be followed by a data byte
with bits defined in Table 15.
The "Read" command allows interrogation of the camera to determine current
configuration.
Any commands not listed should be considered invalid. Writing to invalid
Due to initialization sequencing after power-up, no commands should be
19
03-32-10030-03

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dalstar ds-46-04m30

Table of Contents