Securing An Mvp Panel To An Mvp-Tds - AMX Table Docking Station MVP-TDS Operation/Reference Manual

Table docking station for mvp-7500/8400 modero viewpoint wireless touch panels
Table of Contents

Advertisement

Securing an MVP Panel to an MVP-TDS

The MVP will not be able to communicate with or receive power from the MVP-TDS
without a proper connection.
1. Place the MVP-TDS on a flat and level surface.
2. Provide power to the MVP-TDS (refer to the Powering the MVP-TDS section on page 3).
3. Place the MVP on the support cradle so that the alignment pins on the TDS fit into the matching
holes on the bottom of the MVP.
4. Once proper alignment is verified, gently angle back the MVP until the rear of the panel makes
contact with the electromagnet. Allow one second to activate the electromagnet.
FIG. 4
System message - panel is properly docked
If the MVP is docked properly and communicating, the right LED on the MVP-TDS
will remain brightly illuminated.
Refer to the LED Pattern Indicators for the MVP-TDS table on page 3 for more
information.
If the panel is not securely attached, the electromagnet on the TDS will not be
activated, and the panel could fall forward and be damaged.
MVP-TDS Table Docking Station for MVP Panels
When the MVP is properly docked, the following message is displayed on the panel (FIG. 4).
Proper docking and communication can be verified via the on-screen system message, or the
illuminated Docking Status button on the Protect Setup page, or the right LED on the docking
station.
MVP-TDS Table Top Docking Station
On-screen Docking message
Docking Status button
(illuminates to also give an
indication that the panel is
properly docked)
5