Wiring Legend - Lux Products PSPU721T Instruction Manual

2 heating and 1 cooling with dual fuel switch
Table of Contents

Advertisement

WIRING LEGEND

TERMINAL
EQUIPMENT
Y1
First Heat Pump and AC
G
Fan
W2
First Stage Furnace
OBW
Reverse Valve - Second Stage Furnace
RH
24v
Y2
Not Used
C
Common
H
Not Used
DH
Not Used
RC
24v
11 and 12
Not Used
NOTE: The above colors are standard in HVAC industry. The wiring should be confirmed
before installation
INSTRUCTION MANUAL
STANDARD COLOR
Yellow
Green
White
Orange
Red
Unknown
Blue
Unknown
Unknown
Unknown
9