Combi D.h.w Sequence Of Operation - Baxi Neta-tec Combi GA Range Technical Manual

Neta-tec combi ga range, duo-tec 2 combi ga range, megaflo 2 system ga range gas fired wall mounted condensing combination & system boilers
Table of Contents

Advertisement

Combi Models
D.H.W. Demand
Pump On
Diverter Valve
D.H.W. Position
Fan On
Gas Valve Start
Sequence
Gas Valve Opens
Spark
Ignition
Flame On
Flame Stabilization
Full D.H.W Rate
© Baxi Heating UK Ltd 2012
Pump Check by
Water Pressure - OK
Yes
RPM Check - OK
Yes
No Ignition
5 Seconds
Stabilization
Boiler Operating
3.0 Combi D.H.W. Sequence of Operation
No
E430
No
E160
5 Attempts -
No
Ignition
Achieved
Yes
Loss of
Flame
E133
Reset
12 Attempts -
Ignition
Achieved
Yes
No
E128
Reset
5