Using The Instrument - CST/BERGER SAL20N Instruction Manual

Pal/sal”n” series automatic level
Hide thumbs Also See for SAL20N:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
INTRODUCTION
Thank You for purchasing one of our Automatic Levels.
This manual includes specifications for the PAL and SAL"N" series auto
level. This instrument was carefully inspected and calibrated within tight tol-
erances before shipment. We properly package the instruments for ship-
ment, but we cannot control how the package is handled during shipment.
We advise that you check the instrument using the test shown in the Chapter
"Line-of-Sight" before using. "Measure Twice, Cut Once"...
After doing any job using any instrument, it is advised that you check your
work. To check your work, set up the instrument in a different location from
the place where you originally set up (approx. 16 m) and reshoot a few of
your original targets. The new readings should agree with the first readings.
If the new readings do not agree, you should have the instrument checked
by a CST/berger Authorized Repair Center, or try the Line-of-sight adjust-
ment.

USING THE INSTRUMENT

Setting up the instrument and centering the bubble
1.
Set up the tripod and attach the level using the tripod mounting screw.
2.
Adjust the tripod legs until the tripod head is roughly level. Center the
bubble within the vial by turning the leveling screws as shown in Fig. 2.
2a – Turn screws A and B to move the bubble to the right side.
2b – Turn screw C to center the bubble.
4 • PAL/SALN AutoLevel

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sal24nSal32nSal28nPal22Pal26

Table of Contents