Inspect Auto-Off-Manual; Switch To Control Board Wiring; Check 15 Amp Fuse (F1); Check Battery - Guardian 4721 Repair Manual

1.5l home standby generators
Table of Contents

Advertisement

DC CONTROL
LIQUID COOLED
ENGINE UNITS
CONNECT
ACROSS
SWITCH
TERMINALS
POSITION
1 and 2
AUTO
MANUAL
OFF
1 and 3
AUTO
MANUAL
OFF
4 and 5
AUTO
MANUAL
OFF
4 and 6
AUTO
MANUAL
OFF
RESULTS:
1. Replace switch is defective.
2. If switch is good, go to Test 4.
183
SW1
3
239
1
178
2
178
Figure 2. AUTO-OFF-MANUAL Switch Test Points
SW2
15
15C
178
239
178
183
239
START
15C
183
239
15C
178
178
15A
178
15
Figure 3. AUTO-OFF-MANUAL Switch Wiring
PART 4
METER
READING
Continuity
Infinity
Infinity
Infinity
Continuity
Infinity
Continuity
Infinity
Infinity
Infinity
Continuity
Infinity
6
15
4
15
5
15A
PCB
2 3
4
5 6 7 8
9 10
11
12
13
14 15 16
17
18
178
15C
15E
15E
183
178
TS2
TEST 4 - INSPECT AUTO-OFF-MANUAL

SWITCH TO CONTROL BOARD WIRING

DISCUSSION:
Any open or disconnected wiring between the switch
and the control board, or between the switch and
other components, can have the same effect as an
open or defective switch. See Figure 3.
PROCEDURE:
Inspect and test all wires connected to the switch ter-
minals for open, disconnected or shorted condition.
This includes (a) Jumper Wire 15A between Switch
Terminals 5 and 6; (b) Wire 15 between Terminal 4
and the circuit board; (c) Wire 15A between switch
and circuit board; (d) Wire 183 between Terminal 2
and TB3; (e) Wire 239 between Terminal 1 and the
circuit board; Wire 178 between Terminal 3 and TB3;
(f) Wire 178 between Terminal 3 and the circuit board.
RESULTS:
Repair, reconnect or replace any bad wiring.
TEST 5 - CHECK 15 AMP FUSE (F1)
DISCUSSION:
A blown fuse F1 will open the DC power supply to the
AUTO-OFF-MANUAL switch and to the control board.
This will render the circuit board incapable of cranking
or starting the engine, since its power supply is gone.
PROCEDURE:
Push in on fuse holder cap and turn counterclockwise
to remove cap and fuse. Check the fuse with a VOM
for open condition indicating that fuse is blown.
RESULTS:
1. Replace fuse if blown.
2. If fuse is good but engine won't crank, go on to Test
TEST 6 - CHECK BATTERY
DISCUSSION:
Battery power is used to (a) crank the engine and (b)
to power the control board. Low or no battery voltage
can result in failure of the engine to crank, either
manually or during automatic operation.
PROCEDURE:
A.Inspect battery Cables:
1. Visually inspect battery cables and battery
posts.
2. If cable clamps or terminals are corroded, clean
away all corrosion.
SECTION 4.4
6.
Page 83

Advertisement

Table of Contents
loading

This manual is also suitable for: