Programming

For zone 1,
set the selector to PROG Z1
The 1st time slot flashes on and off.
The program uses 30 min. time slots.
Slot on = Comfort
Slot off = Economy
Repeat for each hour.
E.g. 0.00 to 4.30am in Economy
4.30am to 10.30pm in Comfort
10.30pm to midnight in Economy
Confirm and go to the next day.
Repeat for each day.
To programme zone 2,
repeat these steps with the selector
set to PROG Z2.
Quick programming:
You can assign the current day's program to the following day. Example:
using Monday's program.
Press the
button for about 2 sec. to apply Monday's program to
Tuesday.

Operation with TYPHONE 500

You can call the TYPHONE 500 telephone remote control and let the elec-
tronic voice guide you to determine or modify the status of the heating sys-
tem (see the TYPHONE 500 instructions).
If a change is made via the TYPHONE 500 telephone
remote control, the Delta 200 displays the switchover to
Comfort mode, for example.
To confirm that your TYPHONE 500 is compatible with the DELTA 200,
please call us on +33 (0)2 72 96 03 39.
30 min. of Comfort
30 min. of Economy
- 10 -

Home automation functions

Through the TYDOM 500 home automation gateway, you can associate up
to 16 home automation products (opening detectors, telephone transmitter,
alarm control unit, remote controls, etc.) on the Delta 200.
Operation with a opening detector
You can associate up to 16 opening detectors (maximum number
of home automation products that can be associated).
If one of them is opened, Delta 200 sets the installation
to Frost Protection mode.
Operation with a Tydom 200 remote control
From the home domain
:
You can shut the installation down by pressing the
tactile button.
The shutdown command can be cancelled:
- by pressing the
button,
- by pressing one of the Delta 200 buttons,
- or by changing the position of the Delta 200 selector.
On the AUTO position only:
Pressing the tactile
or
button once will override
the command.
The override is cancelled:
By zone:
- the next time the program switches over in the zone,
- by pressing the
or
button on the Delta 200.
In both zones:
- by changing the position of the Delta 200 selector.
E.g. Comfort override