Setting the temperatures

Setting the temperatures in zone 2

Zone 2 does not have a room sensor, which means that the temperature
setting displayed on Delta 200 is only theoretical. It represents the settings
in relation to the outdoor temperature.
This zone must therefore have thermostatically controlled valves that can
be used to control the room temperature.
Comfort setting
For the Comfort temperature setting, it is advisable to set a value higher
than the highest setting of the thermostatically controlled valves in the zone
(e.g. 21°C).
Set the
knob to
Press the
button.
The Comfort setting for zone 2 is displayed.
Press the
or
buttons to set the new value
(from 5°C to 30°C).
The value is confirmed when no buttons are pressed for 3 seconds.
Economy setting
Set the
knob to
Press the
button.
The Economy setting for zone 2 is displayed.
Press the
or
buttons to set the new value
(from 5°C to 30°C).
The value is confirmed when no buttons are pressed
for 3 seconds.
In this mode,
both zones are in
continuous Comfort mode.
In this mode,
both zones are in continuous
Economy mode.
- 6 -

Setting the Frost Protection temperature

Set the
knob to
The setting applies to both zones at once.
Press the
or
buttons to set the new value (from 5°C to 15°C).
Frost Protection mode can operate in 3 manners:
Zone 1 feed T°
> Setting
or
Frost
Zone 2 return T°
or
protection
Room T°
Zone 1 feed T°
< Setting
or
Frost
Zone 2 return T°
or
protection
Room T°
Outdoor T° < 0°C

Switching off the heating

To switch off the heating (in the summer, for example):
Set the
knob to
DELTA 200 has an anti-seizing function. It switches the circulator on for 3
seconds if it has not operated within the previous 24 hours (useful when
the heating is off).
In this mode, both zones
are incontinuous
Frost Protection mode.
Circulators
Mixer valve
On
Forced closure
Operates
On
according
to the setting
On
Forced opening
This mode keeps pipes from freezing.
The thermostat input control is forced to
shut down. 30 minute cycle every 6 hours.
In this mode, both zones
are shut down.
- 7 -