TOTALINE 1300 Series Installation, Operation And Maintenance Instructions
TOTALINE 1300 Series Installation, Operation And Maintenance Instructions

TOTALINE 1300 Series Installation, Operation And Maintenance Instructions

1300 series electronic air cleaner

Advertisement

IMPORTANT: Read entire instructions before
installing the electronic air cleaner.
IF YOU NEED HELP call toll free: 1-800-565-5326
CONTENTS
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . 1
PACKAGE USAGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Frames with Outer Screens . . . . . . . . . . . . . . . . . . . . . . 2
Collecting Pads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Charging Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
High Voltage Power Supply Box . . . . . . . . . . . . . . . . . . 2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Electronic Air Cleaner Installation. . . . . . . . . . . . . . . . 3
OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
Collecting Pad Replacement . . . . . . . . . . . . . . . . . . . . . 3
TROUBLESHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Im-
proper installation may damage media air cleaner.
Recognize safety information. This is the safety alert
symbol
. When the safety alert symbol is present on equip-
ment or in the instruction manual, be alert to the potential for
personal injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.
Before beginning any installation or modification, be cer-
tain that the main line electrical disconnect switch is in the
OFF position. Electric shock could result. Tag disconnect
switch with suitable warning labels.
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
INSTALLATION,
OPERATION, AND
MAINTENANCE
INSTRUCTIONS
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 2001 12/01
PRINTED IN U.S.A.
Electronic Air Cleaner
Untrained personnel can perform the basic maintenance
functions of replacing collecting pads. All other operations
should be performed by trained service personnel. When work-
ing on air-conditioning equipment, observe precautions in the
literature, tags and labels attached to the unit, and other safety
precautions that may apply.
Follow all safety codes. Wear safety glasses and work
gloves.
PACKAGE USAGE
PART NUMBER
P130-1224C
P130-1424C
P130-1425C
P130-1430C
P130-1520C
P130-1620C
P130-1624C
P130-1625C
P130-1820C
P130-2020C
P130-2024C
P130-2025C
P130-2424C
P130-2425C
P130-2430C
GENERAL
The electronic air cleaner is designed to remove atmospher-
ic and household dust, pollen, mold spores, bacteria, fungi,
insecticide dust, animal dander, coal dust, mites, cooking
smoke and grease, tobacco smoke, and other particles down to
sub-micron levels.
The electronic air cleaner is installed in the furnace filter
rack where a filter would normally be placed. It is designed to
be installed in a 1-in. filter track. Many sizes are available to fit
in different size air ducts.
Airborne pollutants are carried through the return air ducts
of the heating/cooling system to the electronic air cleaner. The
collecting pads of the electronic air cleaner utilize electronic
polarization and ionization to create high filtration efficiencies.
The particles are captured by the collecting pads. The 1-in.
design protects HVAC equipment and their energy efficiencies
due to the electronic air cleaner's low static pressure.
Regular maintenance (replacement or cleaning of collecting
pads) is required by the home owner.
LITERATURE NUMBER P103-4SI
1300 Series
SIZE (in.)
12 x 24
14 x 24
14 x 25
14 x 30
15 x 20
16 x 20
16 x 24
16 x 25
18 x 20
20 x 20
20 x 24
20 x 25
24 x 24
24 x 25
24 x 30
CATALOG NUMBER 570-470

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1300 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for TOTALINE 1300 Series

  • Page 1 INSTALLATION, 1300 Series OPERATION, AND Electronic Air Cleaner MAINTENANCE INSTRUCTIONS Untrained personnel can perform the basic maintenance IMPORTANT: Read entire instructions before functions of replacing collecting pads. All other operations installing the electronic air cleaner. should be performed by trained service personnel. When work-...
  • Page 2: Installation

    COMPONENTS HIGHBOY FURNACE — The filter rack is normally located in the return air duct. See Fig. 1 for a description of the electronic air cleaner. LOWBOY FURNACE — The filter rack is normally located Frames with Outer Screens — in the blower compartment section.
  • Page 3: Maintenance

    Electronic Air Cleaner Installation — After installation of the electronic air cleaner, you may no- Perform the tice some white dust on table tops and shelves. Most heavy following to install the electronic air cleaner. particles (such as lint) settle quickly and do not get filtered 1.
  • Page 4 Fig. 3 — Power Cord Removal Fig. 6 — Opening Corner Fasteners with Key Fig. 7 — Vacuum Outer Screens Fig. 4 — Electronic Air Cleaner Removal Fig. 8 — Install Replacement Collecting Pads Fig. 5 — Collecting Pad Removal...
  • Page 5: Troubleshooting

    TROUBLESHOOTING If the electronic air cleaner stops operating, verify that the green high voltage power supply light is on. If the light is off, check wiring and power supply. Make sure that the power cord is plugged in and connected to the power supply. If the orange LED light is on, perform the Collecting Pad Replacement procedure in the section on page 3.
  • Page 6 ELECTRONIC AIR CLEANER LIMITED TWO-YEAR WARRANTY LIMITED TWO-YEAR WARRANTY — This CARRIER CORPORATION product is warranted to be free from defects in material and workmanship under normal use and maintenance for two years. The warranty does not apply to replacement of the disposable media collecting pads, which will need to be replaced three or four times a year depending on usage.
  • Page 8 Your Assurance of Quality This Totaline® product is backed with a two-year warranty by Carrier Corporation, the world’s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to REPLACEMENT COMPONENTS DIVISION discontinue, or change at any time, ©...

This manual is also suitable for:

P130-1224cP130-1424cP130-1425cP130-1430cP130-1520cP130-1620c ... Show all

Table of Contents