Part Numbers: P103-RRUVL-012, P103-RRUVL-018
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should
install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance func-
tions such as changing lamps. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit or accessory, and other
safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work
gloves.
Before installing accessory or performing maintenance or
service on accessory, turn off main power switch to unit.
Electrical shock can cause injury or death. There may be
more than one disconnect switch.
Never expose eyes or skin to ultraviolet light from any
source. Lamp must be off before entering HVAC (heating,
ventilation, and air conditioning) unit to perform mainte-
nance or service. Personal injury may result.
Do not touch lamp glass without gloves. Wipe lamp clean
after handling.
The lamp contains a small quantity of mercury. If a lamp
breaks, clean area and dispose of lamp with care.
GENERAL
Totaline's Fusion Residential Ultraviolet Air Purifier is
designed to kill odor causing bacteria, viruses, mold and
fungus that may develop in a HVAC unit. The high output, low
temperature air purifier is preferably installed in the return
plenum section of the HVAC unit. It can also be installed in the
supply section. The Fusion Air Purifier is a simple and easy
installation to an existing HVAC unit and incorporates a quick
release mechanism to clean or replace the lamp. See Fig. 1.
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
INSTALLATION
INSTRUCTIONS
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 6-01
PRINTED IN U.S.A.
Fusion Residential Plenum
Ultraviolet Air Purifier
Fig. 1 — Fusion Ultraviolet Air Purifier
INSTALLATION
Location —
The preferred location for installation of the
Fusion Air Purifier is in the return plenum section where it will
have contact with the airstream. If there is an obstruction, such
as the filters, that cannot be relocated, the Fusion Air Purifier
can be installed in the supply, over the evaporator coil. It
should be placed 6 to 10 in. above the coil, so the UV (ultravio-
let) rays will cover the coil.
Make sure site can be supplied with the necessary power
receptacle. Ensure that there is adequate clearance for service.
The Fusion units can be mounted in a horizontal or vertical
position. More than one unit can be used if needed.
Mount Air Purifier on Unit —
procedure to install the air purifier:
1. Turn off all power to unit.
2. Evaluate the ideal area for locating and installing the
Fusion Air Purifier. Ensure that the air purifier will fit
into the plenum. Space required internally is approxi-
mately 12-in. for the size 012 unit and 18-in. for the
size 018 unit. See Fig. 2.
If the drainpan is plastic, it must be protected with a reflec-
tive material, such as metal tape.
3. Ultraviolet light may damage certain plastics and
exposed non-UV-C (Ultraviolet Radiation, C-Band)
protected wires or drainpan. Wrap exposed plastic and
wiring with aluminum tape or use metal conduit.
4. Remove the control box from its package. Open the
cover of the box by loosening the screw 1 or 2 turns to
the left. Swing cover open to allow mounting plate
access.
LITERATURE NUMBER P103-1SI
60 Hz
Perform the following
CATALOG NUMBER 570-455