TOTALINE P102-BB14A Installation, Operation And Maintenance Instructions
TOTALINE P102-BB14A Installation, Operation And Maintenance Instructions

TOTALINE P102-BB14A Installation, Operation And Maintenance Instructions

Residential duct mount builder’s box media air cleaner

Advertisement

IMPORTANT: Read entire instructions before
installing the builder's box media air cleaner.
IF YOU NEED HELP call toll free: 1-800-267-8305
CONTENTS

SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . 1

GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1

COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,2

Cabinet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,3
Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Media Air Cleaner Installation . . . . . . . . . . . . . . . . . . . . 2
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Filter Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Im-
proper installation may damage media air cleaner.
Recognize safety information. This is the safety alert sym-
bol
. When the safety alert symbol is present on equipment
or in the instruction manual, be alert to the potential for person-
al injury.
Understand the signal words DANGER, WARNING, and
CAUTION. These words are used with the safety alert symbol.
DANGER identifies the most serious hazards which will result
in severe personal injury or death. WARNING signifies a haz-
ard which could result in personal injury or death. CAUTION
is used to identify unsafe practices which would result in minor
personal injury or property damage.
Before beginning any installation or modification, be cer-
tain that the main line electrical disconnect switch is in the
OFF position. Electric shock could result. Tag disconnect
switch with suitable warning labels.
Installation and servicing of air-conditioning equipment can
be hazardous due to system pressure and electrical compo-
nents. Only trained and qualified service personnel should in-
stall, repair, or service air-conditioning equipment.
Manufacturer reserves the right to
discontinue, or change at any time,
specifications or designs without notice
and without incurring obligations.
INSTALLATION,
OPERATION, AND
MAINTENANCE
INSTRUCTIONS
Part Numbers: P102-BB14A, P102-BB20
REPLACEMENT COMPONENTS DIVISION
© CARRIER CORPORATION 3/01
PRINTED IN U.S.A.
Residential Duct Mount
Media Air Cleaner
Untrained personnel can perform the basic maintenance
functions of replacing filters. All other operations should be
performed by trained service personnel. When working on air-
conditioning equipment, observe precautions in the literature,
tags and labels attached to the unit, and other safety precautions
that may apply.
Follow all safety codes. Wear safety glasses and work
gloves.
GENERAL
The Builder's Box Media Air Cleaner is designed to re-
move atmospheric and household dust, pollen, mold spores,
bacteria, fungi, insecticide dust, animal dander, coal dust,
mites, cooking smoke and grease, tobacco smoke, and other
particles down to 0.3 micron (1/84,000 in.)
Airborne pollutants are carried through the return air ducts
of the heating/cooling system to the media air cleaner. The par-
ticles are captured by the filter.
The media air cleaner can be easily upgraded to an electronic
air cleaner for additional air filtration. Additional clearance
above the media air cleaner is required for electronic air cleaner
upgrade.
Regular maintenance (replacement of filters) is required by
the home owner.
COMPONENTS
See Fig. 1 for a description of the media air cleaner. See
Table 1 for media air cleaner specifications.
Cabinet —
The cabinet is constructed of heavy gage galva-
nized steel. Holes are provided in the cabinet for easy mounting
in the ductwork or air-handling equipment. See Fig. 2 for cabi-
net dimensions.
Filter —
The filter is constructed of polyolefin fibers that
will not shred or absorb moisture. The unique design of the fil-
ter includes a structured density gradient with a polarized
charge for higher initial and sustained efficiency. The filter me-
dia is supported by an open steel mesh and enclosed by a high
strength, beverage board. The filters have an Underwriters'
Laboratories Class 2 rating.
The efficiency of the filter is based on ASHRAE (American
Society of Heating, Refrigeration and Air Conditioning Engi-
neers) Standard 52.2P. The maximum velocity is 500 ft/min.
An arrow indicates direction of airflow.
LITERATURE NUMBER AC-1SI
Builder's Box
CATALOG NUMBER 570-617

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P102-BB14A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TOTALINE P102-BB14A

  • Page 1 Builder’s Box MAINTENANCE Media Air Cleaner INSTRUCTIONS Part Numbers: P102-BB14A, P102-BB20 Untrained personnel can perform the basic maintenance functions of replacing filters. All other operations should be IMPORTANT: Read entire instructions before performed by trained service personnel. When working on air- installing the builder’s box media air cleaner.
  • Page 2 Table 2 — Media Air Cleaner Pressure Drop (in. wg) PART NUMBER PRESSURE DROP (in. wg) PLASTIC 0.077 KNOB P102-BB14A 1400 0.26 1000 0.079 P102-BB20 2000 0.26 INSTALLATION LOCATION WITH HUMIDIFIER — If a separate humidifier is purchased, it should be installed in the furnace warm air duct.
  • Page 3 AIR FLOW ACCESS DOOR LEFT TO RIGHT RIGHT TO LEFT 7 1/2" UNIT P102-BB14A (435) (660) (25) (55) P102-BB20 (560) (660) (30) (60) Fig. 2 — Dimensions RETURN AIR RETURN AIR RETURN AIR RETURN AIR MEDIA CLEANER MEDIA AIR CLEANER NOTE: Provide a 3 ft (.914 m) clearance for filter removal.
  • Page 4 MAINTENANCE REPLACEMENT PART NUMBER FILTER SIZE (in.) FILTER PART NO. It is very important that the scheduled maintenance be done P102-BB14A P102-1625BB x 25 by the home owner. If the filter is not changed on a regular P102-BB20 P102-2025BB x 25 basis, the media air cleaner will not operate effectively.
  • Page 5 MEDIA AIR CLEANER LIMITED ONE-YEAR WARRANTY LIMITED ONE-YEAR WARRANTY — This CARRIER CORPORATION product is warranted to be free from defects in material and workmanship under normal use and maintenance for one year. The warranty does not apply to replacement of the disposable media filter, which will need to be replaced once or twice a year depend- ing on usage.
  • Page 8 Your Assurance of Quality ALL Totaline® products are backed with a one-year warranty by Carrier Corporation, the world’s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to REPLACEMENT COMPONENTS DIVISION discontinue, or change at any time, ©...