Download Print this page
Mitsubishi Electric PCA-RP·GA Operation Manual
Mitsubishi Electric PCA-RP·GA Operation Manual

Mitsubishi Electric PCA-RP·GA Operation Manual

Mr. slim air-conditioners
Hide thumbs Also See for PCA-RP·GA:

Advertisement

Air-Conditioners
Indoor unit
PCA-RP·GA
PKA-RP·FAL
PKA-RP·GAL

OPERATION MANUAL

For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
BEDIENUNGSHANDBUCH
Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme
gründlich durchlesen.
MANUEL D'UTILISATION
Pour une utilisation correcte sans risques, veuillez lire le manuel d'utilisation en entier avant de vous servir du
climatiseur.
BEDIENINGSHANDLEIDING
Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de
airconditioner gebruikt.
MANUAL DE INSTRUCCIONES
Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado
para garantizar un uso seguro y correcto.
ISTRUZIONI DI FUNZIONAMENTO
Leggere attentamente questi istruzioni di funzionamento prima di avviare l'unità, per un uso corretto e sicuro
della stessa.
E°XEIPI¢IO O¢H°IøN XPH™Eø™
°È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ ÛÂ
ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
MANUAL DE OPERAÇÃO
Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a
unidade de ar condicionado.
DRIFTSMANUAL
Læs venligst denne driftsmanual grundigt før airconditionanlægget betjenes af hensyn til sikker og korrekt brug.
DRIFTSMANUAL
Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
Iflletme Elkitab›
Emniyetli ve do¤ru biçimde nas›l kullan›laca¤›n› ö¤renmek için lütfen klima cihaz›n› iflletmeden önce bu
elkitab›n› dikkatle okuyunuz.
РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ
Для обеспечения правильного и безопасного использования следует ознакомиться с инструкциями,
указанными в данном руководстве по эксплуатации, тщательным образом до того, как приступать к
использованию кондиционера.
Outdoor unit
PUHZ-RP·HA
PU(H)-P·GAA
FOR USER
FÜR BENUTZER
POUR L'UTILISATEUR
VOOR DE GEBRUIKER
PARA EL USUARIO
PER L'UTENTE
°π∞ ∆√¡ Ã∏™∆∏
PARA O UTILIZADOR
TIL BRUGER
FÖR ANVÄNDAREN
KULLANICI ‹Ç‹N
ДЛЯ ПОЛЬЗОВАТЕЛЯ
(
)
English
∂ÏÏËÓÈο
Русский

Advertisement

loading

Summary of Contents for Mitsubishi Electric PCA-RP·GA

  • Page 1: Operation Manual

    Air-Conditioners Indoor unit Outdoor unit PCA-RP·GA PUHZ-RP·HA PKA-RP·FAL PU(H)-P·GAA PKA-RP·GAL OPERATION MANUAL FOR USER English For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit. BEDIENUNGSHANDBUCH FÜR BENUTZER Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen.
  • Page 2: Table Of Contents

    Contents 1. Safety Precautions ..................................2 2. Operation ..................................... 3 3. Care and cleaning ..................................5 4. Troubleshooting ................................... 7 5. Specifications ....................................8 1. Safety Precautions s Before installing the unit, make sure you read all the “Safety precautions”. s The “Safety precautions”...
  • Page 3: Operation

    2. Operation Replacing the Batteries and how to set the current time If no signal is transmitted and the indoor unit’s lamp does not light up even if the remote controller is operated, the batteries may have run out, so replace them with new ones as described below.
  • Page 4 2. Operation 2.4. Selecting a fan speed 1 Press button to select a desired fan speed. • Each time you press the button, available options change with the dis- play A on the remote controller, as shown below. ˚C Remote controller display Fan speed ˚C Middle 2*...
  • Page 5: Care And Cleaning

    2. Operation For wireless remote controller AUTO STOP AUTO START 1Press the button (TIMER SET). • Time can be set while the following symbol is blinking. OFF timer : A is blinking. ON timer : A is blinking. 2 Use the buttons to set the desired time.
  • Page 6 3. Care and cleaning 3.2. Care and cleaning Clean the filter When the A “FILTER” indicator blinks on the remote controller to alert you to the necessity of cleaning of the filter. ∗ As a guideline for typical office environment, the filter must be cleaned ˚C every 100 operating hours.
  • Page 7: Troubleshooting

    4. Troubleshooting Before you call out a repair man, check the following table to see whether there is a simple solution to your problem. [for wireless remote controller] Problem Solution Problem Solution Unit does not operate at all. Turn main power on. Then press the Unit does not start immediately.
  • Page 8: Specifications

    5. Specifications I PCA-RP·GA+PU(H)-P·GAA Model RP2.5 Capacity (Cooling/Heating) <kW>*1 5.35/6.20 6.60/7.25 7.45/9.15 9.60/10.60 12.30/14.80 14.20/17.00 Total Input (Cooling/Heating) <kW>*1 2.35/2.36 2.62/2.66 3.37/3.48 3.62/3.81 4.91/5.11 5.89/6.24 Power source (voltage <V>/Frequency <Hz>) – Dimension (Height) <mm> Dimension (Width) <mm> 1000 1310 1620 Dimension (Depth) <mm>...
  • Page 9 5. Specifications I PKA-RP·FAL+PU(H)-P·GAA Model RP2.5 Capacity (Cooling/Heating) <kW>*1 6.45/7.35 7.85/9.40 9.40/10.80 Total Input (Cooling/Heating) <kW>*1 2.65/2.63 3.43/3.61 3.59/3.77 Power source (voltage <V>/Frequency <Hz>) – Dimension (Height) <mm> Dimension (Width) <mm> 1400 1680 Dimension (Depth) <mm> Fan Airflow rate (Low-High) <m /min>...
  • Page 12 This product is designed and intended for use in the residential, commercial and light-industrial environment. • Low Voltage Directive 73/23/ EEC The product at hand is • Electromagnetic Compatibility Directive 89/ based on the following 336/ EEC EU regulations: Please be sure to put the contact address/telephone number on this manual before handing it to the customer.