Payne 018-060 PA10 Installation Manual
Payne 018-060 PA10 Installation Manual

Payne 018-060 PA10 Installation Manual

Electric air conditioner

Advertisement

Quick Links

NOTE: Read the entire instruction manual before starting the installation.
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may
cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or
assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual
instructions packaged with the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Use quenching cloth for brazing operations. Have fire
extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.
Consult local building codes and National Electrical Code (NEC) for special requirements.
Recognize safety information. This is the safety-alert symbol
to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION, AND NOTE. These words are used with the safety-alert symbol. DANGER
identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage. NOTE
is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
WARNING: Before installing or servicing system, always turn off main power to system. There may be more than 1
disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death.
NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment.
1. Locate unit away from windows, patios, decks, and so forth, where unit-operation sound may disturb customer.
2. Ensure that vapor- and liquid-tube diameters are appropriate to capacity of unit.
3. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends.
4. Leave some slack between structure and unit to absorb vibration.
5. When passing refrigerant tubes through the wall, seal opening with RTV or other pliable silicon-based caulk. (See Fig. 1.)
6. Avoid direct tubing contact with water pipes, duct work, floor joists, wall studs, floors, and walls.
7. Do not suspend refrigerant tubing from joists and studs with a rigid wire or strap that comes in direct contact with tubing. (See Fig. 1.)
8. Ensure that tubing insulation is pliable and completely surrounds vapor tube.
9. When necessary, use hanger straps which are 1 in. wide and conform to shape of tubing insulation. (See Fig. 1.)
10. Isolate hanger straps from insulation by using metal sleeves bent to conform to shape of insulation.
CAUTION: DO NOT BURY MORE THAN 36 IN. OF REFRIGERANT TUBING IN GROUND. If any section of tubing is
buried, there must be a 6-in. vertical rise to valve connections on outdoor unit. If more than recommended length is buried,
refrigerant may migrate to cooler buried section during extended periods of unit shutdown, causing refrigerant slugging and
possible compressor damage at start-up.
PROCEDURE 1—CHECK EQUIPMENT AND JOB SITE
A. Unpack Unit
Move to final location. Remove carton taking care not to damage unit.
B. Inspect Equipment
File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit control box access
panel. It contains information needed to properly install unit. Check rating plate to be sure unit matches job specifications.
Form: IM-PA10-04
Cancels: IM-PA10-03/IM-PA12-01

Installation Manual

Electric Air Conditioner
018-060 PA10
024-060 PA12

SAFETY CONSIDERATIONS

INSTALLATION RECOMMENDATIONS

. When you see this symbol on the unit and in instructions or manuals, be alert

INSTALLATION

Printed in U.S.A.
PA10
PA12
6-01
Catalog No. 53PA-1012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 018-060 PA10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Payne 018-060 PA10

  • Page 1: Installation Manual

    Installation Manual Electric Air Conditioner PA10 018-060 PA10 PA12 024-060 PA12 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage.
  • Page 2 NOTE: Avoid contact between tubing and structure OUTDOOR WALL INDOOR WALL CAULK LIQUID TUBE VAPOR TUBE INSULATION THROUGH THE WALL JOIST HANGER STRAP (AROUND VAPOR INSULATION TUBE ONLY) VAPOR TUBE 1″ MIN. LIQUID TUBE SUSPENSION A94028 Fig. 1—Connecting Tubing Installation NOTE: Check to be certain factory tubing on both indoor and outdoor unit has not been shifted during shipment.
  • Page 3 AIR IN AIR DISCHARGE AIR IN 3/8” DIA. TIEDOWN KNOCKOUTS AIR IN AIR DISCHARGE 2 15/16 7/16 AIR IN 2 3/4 A01340 UNIT SIZE PA12 024 - 060 23-1/2 6-1/2 PA10 018 - 048 22-1/2 18-1/2 8-3/16 4-1/16 PA10 060 23-1/2 6-1/2 Fig.
  • Page 4 Table 1—Refrigerant Connections and Recommended Liquid and Vapor Tube Diameters (In.) LIQUID VAPOR UNIT SIZE Connect Tube Connect Tube Diameter Diameter Diameter Diameter 018, 024 030, 036 042–048 1-1/8 Note: Tube diameters are for lengths up to 60 ft. For tubing lengths greater than 60 ft, consult your local distributor or Long-Line Application Guideline. C.
  • Page 5 A00010 Fig. 4—3 Phase Monitor Control Table 2—Phase Monitor LED Indicators STATUS No call for compressor operation FLASHING Reversed phase Normal CAUTION: Compressor damage may occur if system is overcharged. CAUTION: Do not vent refrigerant to atmosphere. Recover during system repair or final unit disposal. CARE AND MAINTENANCE For continuing high performance, and to minimize possible equipment failure, it is essential that periodic maintenance be performed on this equipment.
  • Page 6 HEAT STAGE 1 HEAT STAGE 1 COOL STAGE 1 COOL STAGE 1 INDOOR FAN INDOOR FAN A01333 A01334 Fig. 5—Typical 24v Circuit Connections —6— © 2001 Payne Heating & Cooling P.O. Box 70, Indianapolis, IN 46206 impa1004 Catalog No. 53PA-1012...

This manual is also suitable for:

024-060 pa12

Table of Contents