Indoor Fan Motor Control - Toshiba RAS-M10SKV-E Service Manual

High wall, heat pump type; high wall, coolingtype
Hide thumbs Also See for RAS-M10SKV-E:
Table of Contents

Advertisement

Item
2. Indoor fan
<In cooling operation>
motor control
(This operation controls the fan speed at indoor unit side.)
The indoor fan (cross flow fan) is operated by the phase-
control induction motor. The fan rotates in 5 stages in
MANUAL mode, and in 5 stages in AUTO mode, respec-
tively. (Table 1)
COOL ON
Fan speed setup
AUTO
Ta
[ ˚C ]
+2.5
a
+2.0
b
+1.5
c
+1.0
d
+0.5
e
Tsc
Fan speed
level
WF
WE
WD
WC
WB
WA
W9
W8
W7
W6
W5
W4
W3
W2
W1
Operation flow and applicable data, etc.
MANUAL
Indication
L
L+
M
M+
H
Air volume AUTO
M+(WB)
*3
*3 : Fan speed = (M + –L) x 3/4 + L
*4
*4 : Fan speed = (M + –L) x 2/4 + L
*5
*5 : Fan speed = (M + –L) x 1/4 + L
(Linear approximation
L(W6)
from M+ and L)
(Table 1) Indoor fan air flow rate
RAS-M10SKV-E
RAS-M10SKCV-E
COOL HEAT DRY
Fan speed
(rpm)
UH
1240
H
1170
UH
M+
1140
H
1100
M+
1000
M
1000
M
L+
960
L
870
L+
L-
L+
850
L
L
760
L-
UL
L-
760
UL
UL
700
SUL
SUL
650
SUL
500
500
(Fig. 1)
Fan speed
W6
(L + M) / 2
W9
(M + H) / 2
WC
(Fig. 2)
RAS-M13SKV-E
RAS-M13SKCV-E
Air flow rate
Fan speed
Air flow rate
(m3/h)
(rpm)
(m3/h)
630
1240
630
582
1240
630
563
1190
596
536
1140
563
469
1040
496
469
100
469
443
960
443
383
870
383
369
850
369
309
760
309
309
760
309
269
700
269
236
650
236
135
500
135
135
500
135
– 28 –
Description
* Symbols
UH
: Ultra High
H
: High
M+
: Medium+
M
: Medium
L+
: Low+
L
: Low
L-
: Low–
UL
: Ultra Low
SUL
: Super Ultra Low
* The fan speed broadly varies due
to position of the louver, etc.
The described value indicates one
under condition of inclining
downward blowing.
1) When setting the fan speed to L,
L+, M, M+ or H on the remote
controller, the operation is
performed with the constant
speed shown in Fig. 1.
2) When setting the fan speed to
AUTO on the remote controller,
revolution of the fan motor is
controlled to the fan speed level
shown in Fig. 2 and Table 1
according to the setup tempera-
ture, room temperature, and heat
exchanger temperature.
RAS-M16SKV-E
RAS-M16SKCV-E
Fan speed
Air flow rate
(rpm)
(m3/h)
1470
743
1470
743
1440
723
1390
691
1250
601
1190
563
1120
518
970
421
950
408
890
370
870
357
810
318
750
280
600
183
500
119