INTELIA
Level 0 (LED)
Description :
Verify keyboard LED
Action :
LED ON/OFF always blink during the test.
The others LED blink once, then only one LED is ON starting from No Water, Error, Double, No
Beans, Dump Box, Calc Clean, Steam, Coffee, Espresso, Hot Water.
The sequence is always repeated.
Note
LED
COLOR
No Water
RED
Error
RED
Double
GREEN
No Beans
RED
Dump Box
RED
Calc Clean
YELLOW
Steam
GREEN
Coffee
GREEN
Espresso
GREEN
Hot Water
GREEN
ON/OFF
RED
On ERROR verify:
Cable connection
Power supply
Driver 74HC595 presence and welding
Driver 74HC595 orientation
LED presence and welding
LED orientation
Polarization resistor presence and welding
Level 1 (Buttons) [LED No Water ON]
Description:
Verify the keyboard buttons (each button has a rear LED)
Action:
Pressing the button where the rear LED is ON changes the LED OFF, follow the moving LED
If you are not able to turn the LED OFF detects an error condition over the button switch
Start condition
All LED are OFF
On ERROR verify:
Cable connection
Power supply
Push button presence and welding
Saeco International Group
Pressing ON/OFF button moves to next level
Pressing ON/OFF button moves to next level
Rev. 03
05 TROUBLESHOOTING
Page
18
/ 22