Download Print this page

Bryant ERVBBSVB Product Data

Energy recovery ventilators/heat recovery ventilators

Advertisement

Quick Links

ERVBBSVB, ERVBBSHB
ENERGY RECOVERY VENTILATORS
HRVBBSVB, HRVBBSHB
HEAT RECOVERY VENTILATORS
Fig. 1 - - ERVBBSVB / HRVBBSVB
Fig. 2 - - ERVBBSHB / HRVBBSHB
Product Data
Energy Recovery Ventilation (ERV) and Heat Recovery Ventilation
(HRV) systems offered by Bryant are the finest on the market
today. These units provide efficient and cost effective heat and
energy recovery during the heating and cooling season when
needed most.
As temperatures drop below 23_F (- -5_C), indoor air is recirculated
periodically through the heat exchanger core to prevent frost from
forming. Competitors' methods of supplementary electric defrost
waste energy. Unlike rotary wheel heat exchangers which mix air
streams, these cross- -flow or counterflow heat exchangers ensure
that there is no mixing of the stale air stream with the fresh outdoor
air stream.
A filter installed on the incoming outdoor air stream removes large
airborne particles from the intake air stream before they enter the
A05229
heat exchanger and reduces the maintenance required. The units'
acoustically engineered design makes the Bryant ERVs and HRVs
are the quietest on the market and ensures that comfort is felt, not
heard.
Unlatching two (2) suitcase style latches allows easy removal of the
filters and core for cleaning.
NOTE:
unconditioned space unless provisions are made for drain- -line
freezing and condensation.
S Drainless design - - ERVs / Drains provided - - HRVs
S Integrated airflow balancing points
S High pressure blowers
S Onboard control for continuous high/low ventilator operation
S Energy saving defrost cycle
A05330
S Cross- -flow, counterflow heat exchangers
S One filter on incoming air; one filter on outgoing air to protect
core
S No- -tools maintenance
S Enthalpic heat exchanger core - - ERVs
S Polypropylene heat exchanger core - - HRVs
The HRV should not be installed in an attic or
STANDARD FEATURES

Advertisement

loading

Summary of Contents for Bryant ERVBBSVB

  • Page 1 Product Data Energy Recovery Ventilation (ERV) and Heat Recovery Ventilation (HRV) systems offered by Bryant are the finest on the market today. These units provide efficient and cost effective heat and energy recovery during the heating and cooling season when needed most.
  • Page 2: Model Number Nomenclature

    100 --- 100 CFM HRV - - Heat Recovery Ventilator Electrical Supply Brand 1 - - 115 Volts BB - - Bryant Style SHB - - Small Horizontal SVB - - Small Vertical Climate Map for Energy and Heat Recovery Ventilators...
  • Page 3 VENTILATOR ACCESSORY NUMBER NOMENCLATURE Product Control Description KV - - Ventilator Accessory Kit BBS - - Bryant Basic Control BLC - - Bryant Latent Control Series BLT - - Bryant OneTouch Control A - - Original Series BST - - Bryant Standard Control...
  • Page 4 Fig. 3 - - ERVBBSHB and HRVBBSHB Unit Dimensions Key to Unit Port Locations Fresh air to building Stale air from building Fresh air from outside Stale air to outside Top View Side View A10099 Fig. 4 - - ERVBBSVB and HRVBBSVB Unit Dimensions...
  • Page 5: Physical Data

    PHYSICAL DATA MODEL ERVBBSVB1100 ERVBBSHB1100 HRVBBSVB1100 HRVBBSHB1100 Port Locations Side Side Enthalpic transfer media Enthalpic transfer media Polypropylene Cross Polypropylene Cross Core Type with plastic stack with plastic stack Flow Flow Core Exchange Area 56 sq. ft. (5.2m 56 sq. ft. (5.2m 55 sq.
  • Page 6: Performance Data

    PERFORMANCE DATA HVI Rated Energy Performance LATENT POWER SENSIBLE APPARENT TOTAL SUPPLY TEMP NET AIR FLOW RECOVERY CONSUMED RECOVERY SENSIBLE RECOVERY MODEL MODE MOISTURE (WATTS) EFFICIENCY EFFECTIVENESS EFFICIENCY TRANSFER 0.63 0.58 Heating 0.48 ERVBBSHB1100 ---25 ---13 0.60 Cooling 0.63 0.58 Heating 0.48 ERVBBSVB1100...
  • Page 7 VENTILATOR INSTALLED WITH FORCED AIR SYSTEM A10105 VENTILATOR INSTALLED WITH INDEPENDENT AIR DISTRIBUTION A10106...
  • Page 8 Catalog No. PDSERVHRV ---01 E2010 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 05/10 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.