Bryant EVOLUTION 986TA Product Data page 6

A series two-stage 4-way multipoise, variable speed condensing
Hide thumbs Also See for EVOLUTION 986TA:
Table of Contents

Advertisement

AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) (CONTINUED)
INPUT
Cooling Switch Settings
BTUH
SW2-3
SW2-2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
100000
ON
ON
ON
ON
Maximum Cooling Airflow
High Heat Airflow
Low Heat Airflow
Cooling Switch Settings
INPUT
BTUH
SW2-3
SW2-2
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
6
120000
ON
OFF
ON
ON
ON
ON
Maximum Cooling Airflow
High Heat Airflow
Low Heat Airflow
1. Nominal 350 CFM/ton cooling airflow is delivered with SW1-5 and SW4-3 set to OFF.
Set both SW1-5 and SW4-3 to ON for +7% airflow (nominal 370 CFM/ton).
Set SW1-5 to ON and SW4-3 to OFF for +15% airflow (nominal 400 CFM/ton).
Set SW4-3 to ON and SW1-5 to OFF for -7% airflow (nominal 325 CFM/ton).
2. Maximum cooling airflow is achieved when switches SW3-1, SW3-2, SW3-3 and SW1-5 are set to ON, and SW4-3 is set to OFF.
3. All heating CFM's are when low heat rise adjustment switch (SW1-3) and comfort/efficiency adjustment switch (SW1-4) are both set to OFF.
4. Ductwork must be sized for high-heating CFM within the operational range of E.S.P. Operation within the blank areas of the chart is not recommended
because high-heat operation will be above 1.0 E.S.P.
5. All airflows on 21" (533 mm) casing size furnaces are 5% less on side return only installations.
6. Side returns for 24.5" (622 mm) casing sizes require two sides, or side and bottom, to allow sufficient airflow at the return of the furnace.
7. Airflow not stable at this E.S.P.
(SW1-5 and SW4-3 set to OFF, except as indicated. See Notes 1 and 2.)
SW2-1
0.1
0.2
OFF
2115
2035
ON
870
715
OFF
1025
950
ON
1210
1165
OFF
1400
1355
ON
1615
1570
OFF
2115
2035
ON
2115
2035
2
2115
2035
3
2115
2035
3
1575
1530
SW2-1
0.1
0.2
OFF
2010
1960
ON
1015
805
OFF
1075
975
ON
1205
1135
OFF
1400
1330
ON
1615
1550
OFF
2010
1960
ON
note 7
2375
2
note 7
2375
3
note 7
2375
3
1735
1675
External Static Pressure (E.S.P .)
0.3
0.4
0.5
1965
1890
1805
1725
585
525
450
900
835
770
1105
1055
1000
950
1295
1250
1205
1155
1525
1485
1435
1395
1965
1890
1805
1725
1965
1890
1805
1725
1965
1890
1805
1725
1965
1890
1805
1725
1485
1445
1395
1350
External Static Pressure (E.S.P .)
0.3
0.4
0.5
1910
1850
1800
1750
645
550
480
915
835
765
1055
1000
935
1260
1190
1145
1080
1500
1435
1370
1325
1910
1850
1800
1750
2300
2205
2115
2010
2300
2205
2115
2010
2300
2205
2115
2010
1625
1560
1500
1455
6
0.6
0.7
0.8
0.9
1625
1540
1435
895
845
800
1110
1060
1020
1345
1310
1260
1625
1540
1435
1625
1540
1435
1625
1540
1435
1625
1540
1435
1305
1265
1215
0.6
0.7
0.8
0.9
1690
1645
1565
1035
970
905
1265
1215
1160
1690
1645
1565
1890
1750
1645
1890
1750
1645
1890
1750
1645
1395
1345
1285
1.0
1345
735
960
1210
1345
1345
1345
1345
1165
1.0
1480
845
1110
1480
1550
1550
1550
1225