A. ELECTRIC MOTOR: The motor is used to power the pump. It has a thermal overload protector and an
automatic reset. If the motor overheats for any reason, the thermal overload protector will shut it down
to prevent the motor from being damaged. The motor will automatically restart when it completely
cools.
AIR COMPRESSOR PUMP: The pump is used to compress the air and discharge it into the tank via
the piston moving up and down in the cylinder.
B. ON/OFF SWITCH: This switch turns on the compressor. It is operated manually, but when in the ON
position, it allows the compressor to start up or shut down automatically, without warning, upon air
demand. ALWAYS set this switch to OFF when the compressor is not being used, and before
unplugging the compressor.
C. AIR LINE OUTLET: The outlet is used to connect 1/4" NPT air hose.
D. REGULATED PRESSURE GAUGE: The gauge is used to measure the regulated outlet pressure.
E. TANK PRESSURE GAUGE: The gauge is used to measure the pressure level of the air stored in the
tank. It is not adjustable by the operator, and does not indicate line pressure.
F. AIR PRESSURE REGULATOR: The regulator is used to adjust line pressure to the tool you are using.
Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.
WARNING:Never exceed the maximum working pressure of the tool.
G. PRESSURE RELIEF VALVE: The valve is used to prevent system failures by relieving pressure from
the system when the pressure reaches the preset level while the pressure switch does not shut down
the motor. It will pop open automatically or you can pull the ring on the valve to make it.
H. AIR TANK: The tank is used to store the compressed air.
I.
AIR TANK DRAIN VALVE: The drain valve is used to remove moisture from the air tank after the unit is
shut off.
WARNING:Never attempt to open the drain valve when over 10 PSI of air pressure is in the tank.
J. POWER CORD: This product is for use on a nominal 120-volt circuit and should be grounded. A cord
with a grounding plug shall be used. Make sure that the product is connected to an outlet having the
same configuration as the plug (see Figure 1). No adapter should be used with this product.
Check with a licensed electrician if the grounding instructions are
not completely understood, or if in doubt as to whether the product
is properly grounded. Do not modify the plug provided. If it will not
fit the outlet, have the proper outlet installed by a licensed
electrician.
DANGER:
Improper installation of the grounding plug will result
in a risk of electric shock. If repair or replacement of the cord or plug
is necessary, do not connect the grounding wire to either flat blade
terminal. The grounding wire is in green outer surface.
BASIC COMPRESSOR FEATURES
-Page 5-
Grounded
outlet
Plug
115V/2.0 A
Grounding Pin
Figure 1