MICOM function and circuit description
5-2-9. Storing temperature compensation and over-cool/under-cool cut compensation circuit
(1) Storing temperature compensation
u This is the circuit to input the temperature compensation level required for adjusting storage temperature at the left or
right compartment of the lid or drawer.
Lid left compartment
(RCUL)
u Temperature compensation table by adjustment of resistance value (difference against current temperature)
Ex) If you change the resistance of compensation at the lid left compartment (RCL) from 10KΩ (current resistance) to
18KΩ (adjusted resistance), the storage temperature in the lid left compartment will be increased by 1°C .
Modified
resistance
470 Ω
Classification
Current
resistance
470KΩ
No change
Lid left
2 KΩ
0.5°C DOWN No change
compartment
3.3 KΩ
1°C DOWN 0.5°C DOWN No change
(RCUL)
5.6 KΩ
1.5°C DOWN 1°C DOWN 0.5°C DOWN No change 0.5°C UP
Lid right
compartment
8.2 KΩ
2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
(RCUR)
10 KΩ
2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
Drawer left
compartment
12 KΩ
3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change 0.5°C UP
(RCBL)
18 KΩ
3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
Drawer right
compartment
33 KΩ
4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
(RCBR)
56 KΩ
4.5°C DOWN 4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
180 KΩ
5°C DOWN 4.5°C DOWN 4°C DOWN 3.5°C DOWN 3°C DOWN 2.5°C DOWN 2°C DOWN 1.5°C DOWN 1°C DOWN 0.5°C DOWN No change
Lid right compartment Drawer left compartment Drawer right compartment
(RCUR)
(RCBL)
180 KΩ
56 KΩ
33 KΩ
18 KΩ
12 KΩ
10 KΩ
8.2 KΩ
5.6 KΩ
3.3 KΩ
2 KΩ
470 Ω
2 KΩ
3.3 KΩ
5.6 KΩ
0.5°C UP
1°C UP
1.5°C UP
0.5°C UP
1°C UP
0.5°C UP
Temperature
compensation value
(RCBR)
+2.5 ˚C
+2.0 ˚C
+1.5 ˚C
+1.0 ˚C
+0.5 ˚C
0 ˚C
-0.5 ˚C
-1.0 ˚C
-1.5 ˚C
-2.0 ˚C
-2.5 ˚C
8.2 KΩ
10 KΩ
12 KΩ
2°C UP
2.5°C UP
3°C UP
1.5°C UP
2°C UP
2.5°C UP
1°C UP
1.5°C UP
2°C UP
1°C UP
1.5°C UP
0.5°C UP
1°C UP
0.5°C UP
- 20 -
Remarks
Warmer
Standard temperature
Cooler
18 KΩ
33 KΩ
56 KΩ
3.5°C UP
4°C UP
4.5°C UP
3°C UP
3.5°C UP
4°C UP
2.5°C UP
3°C UP
3.5°C UP
2°C UP
2.5°C UP
3°C UP
1.5°C UP
2°C UP
2.5°C UP
1°C UP
1.5°C UP
2°C UP
1°C UP
1.5°C UP
0.5°C UP
1°C UP
0.5°C UP
180 KΩ
5°C UP
4.5°C UP
4°C UP
3.5°C UP
3°C UP
2.5°C UP
2°C UP
1.5°C UP
1°C UP
0.5°C UP