Accessory Usage Guideline - Carrier 38YCC Product Data

50 hz heat pump sizes 024 thru 060
Table of Contents

Advertisement

Accessory usage guideline

ACCESSORY
Crankcase Heater
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
Low Ambient Controller
or
MotorMaster® Control
Wind Baffle
Support Feet
Liquid-Line Solenoid Valve
or
Hard Shutoff TXV
* For tubing line sets between 50 and 175 ft (15.24 and 53.34m), refer to Residential Split-System Long-Line Application Guideline.
† For buried line applications, refer to Residential Split System Buried Line Application Guideline.
‡ Only when low-pressure switch is used.
Accessory description and usage (Listed alphabetically)
1. Compressor Start Assist — Capacitor and Relay
Start capacitor and start relay gives "hard" boost to compressor motor at each start-up.
SUGGESTED USE: Installations where interconnecting tube length exceeds 50 ft (15.24m).
Installations where outdoor design temperature exceeds 105 ° F (40.6 ° C).
Replacement installations with hard shutoff expansion valve on indoor coil.
Installations where Liquid-Line Solenoid Valve has been added.
Units installed with Low-Ambient Controller.
2. Compressor Start Assist — PTC
Solid-state electrical device which gives a "soft" boost to compressor motor at each start-up.
SUGGESTED USE: Installations with marginal power supply.
Replacement installations with rapid pressure balance (RPB) expansion valve on indoor coil.
3. Cycle Protector
Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor
has been interrupted for any reason, including normal room thermostat cycling.
SUGGESTED USE: Installations in areas where power interruptions are frequent.
Where user is likely to "play" with room thermostat.
All commercial installations.
Installations where interconnecting tube length exceeds 50 ft (15.24m).
High-rise applications.
4. Evaporator Freeze Thermostat
An SPST temperature actuated switch which stops unit operation when evaporator reaches freeze-up conditions.
SUGGESTED USE: All units where Winter Start Control has been added.
All units where Low-Ambient Controller has been added.
5. Filter Drier—Bi-Flow
A device for removing contaminants from refrigerant circulating in a heat pump system: 2-direction flow.
SUGGESTED USE: All split-system heat pumps.
6. High-Pressure Switch
Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to about
426 ± 7 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. To prevent rapid compressor
recycling, Cycle Protector can be used with this switch.
SUGGESTED USE: Installations exposed to very "dirty" outdoor air.
Installations where condenser inlet air temperature exceeds 125 ° F (51.7 ° C).
7. Interface Control (Optimizer II®)
An electric control for controlling a heat pump and gas or oil furnace system for maximum energy savings. It allows heat pump to operate down to a
predetermined economic balance point temperature, then switches to allow furnace operation only below that temperature. Requires outdoor thermostat
to be adjusted for economic balance point temperature.
SUGGESTED USE: All heat pump and gas- or oil-fired furnace combination systems.
8. Isolation Relay
An SPDT relay which switches the Low-Ambient Controller out of the outdoor fan motor circuit when heat pump switches to heating mode.
SUGGESTED USE: All heat pumps where Low-Ambient Controller has been added.
9. Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor unit and which stops and starts refrigerant liquid flow in response to compressor
operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
NOTE: Compressor Start Assist–Capacitor and Relay must also be used.
SUGGESTED USE: In certain long-line applications. Refer to Residential Split System Long-Line Application Guideline.
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55 ° F/12.8 ° C)
Yes
Yes
Yes‡
No
Yes
Yes
See Low-Ambient Instructions
Recommended
No
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft/15.24m)
Yes
No
No
No
Yes
No
No
No
See Long-Line
Application
Guideline
REQUIRED FOR
BURIED LINE
APPLICATIONS†
(Over 3 Ft/0.914m)
Yes
No
No
Yes
Yes
No
No
No
Yes
5