OPERATING YOUR HEAT RECOVERY VENTILATOR (HRV)
Your HRV is designed to operate as an integral part of your total heating and cooling system. With the exception of high capacity
models, which are available with standard controls only, all HRVs offer 3 control options (See Fig. 1.):
Basic Controls: Allow the user to manually set the unit to low- or high-fan speed as required to maximize comfort. Controls may
be unit mounted.
Standard Controls: Offer automatic dehumidistat control and the option to select low speed or intermittent fan during heating season.
Automatic Controls: In addition to the operational features found with standard controls, automatic controls feature a recircula-
tion mode. Not for use with forced-air HVAC systems.
Fan Speed Control —Enables user to modulate fan speed from low to high.
Dehumidistat Control —Allows the user to select the relative humidity level at which the unit would change fan speed to avoid
condensation problems while heating during the winter months.
OUTSIDE TEMPERATURE
°C
10
0
–10
–20
–30
Continuous Mode —If the relative humidity inside the building is lower than selected, air exchange would occur with the outside
at low speed. If the relative humidity level inside the building is higher than selected, air exchange would occur outside at high
speed. This ensures continuous air exchange for constant air quality.
Intermittent Mode —If the relative humidity inside the building is lower than selected, no air exchange would occur, and the sys-
tem would turn off. If the relative humidity inside the building is higher than selected, air exchange would occur with outside at
high speed. This ensures minimum air exchange level when the building is unoccupied to minimize operating cost.
Recirculation Mode —If the relative humidity inside the building is lower than selected, indoor air would be circulated and filtered
at high speed. If the relative humidity inside the house is higher than selected, air exchange would occur with outside at high speed.
This ensures continuous movement and filtration of air for maximum comfort.
HRVBBSVU, AND HRVBBLVU
HEAT RECOVERY VENTILATOR
User's Information Manual for the Operation and
Maintenance of Heat Recovery Ventilators
70
80
OFF
LOW
HIGH
20
25
´
% D HUMIDITE RELATIVE HUMIDITY
´
BASSE
HAUTE
% HUM. RELATIVE HUM.
55%
45%
35%
30%
Standard Control
Fig. 1 — Controls
TABLE 1 — HUMIDITY SETTINGS
°F
50
32
14
–24
–22
USER'S INFORMATION MANUAL
MODELS HRVBBLHU,
60
AIR EXCHANGE
ON
´
ECHANGE D´AIR
MARCHE
50
40
30
OFF
LOW
ARRET
BASSE
INTERMITTENT
EXT. TEMP. EXT.
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4 °F
DOUBLE-PANE WINDOWS
(PERCENTAGE)
55
45
35
30
25
MODE
AIR EXCHANGE
ECHANGE D´AIR
´
% HUM. RELATIVE HUM.
EXT. TEMP. EXT.
55%
50
40
45%
35%
60
30
30%
70
25
20
80
´
% D´HUMIDITE RELATIVE HUMIDITY
Automatic Control
TRIPLE-PANE WINDOWS
(PERCENTAGE)
65
55
45
40
35
10°C/50°F
0°C/32°F
–10°C/14°F
–20°C/–4 °F
A00030

Advertisement

loading

Summary of Contents for Bryant HRVBBLHU

  • Page 1 USER’S INFORMATION MANUAL MODELS HRVBBLHU, HRVBBSVU, AND HRVBBLVU HEAT RECOVERY VENTILATOR User’s Information Manual for the Operation and Maintenance of Heat Recovery Ventilators MODE AIR EXCHANGE ´ ECHANGE D´AIR MARCHE HIGH AIR EXCHANGE ECHANGE D´AIR ´ % HUM. RELATIVE HUM.
  • Page 2 BRIEF CASE TYPE LATCH A99300 A92382 Fig. 2 — Vertical Application Fig. 3 — Horizontal Application © 2000 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls., IN 46231 Form: OM17-27 Cancels: New Printed in U.S.A. 2-00 Catalog No. 13HR-VB0...

This manual is also suitable for:

HrvbbsvuHrvbblvuVa3bVa5bVc5b