Download Print this page

Bryant 315AAV Quick Manual page 8

Sizes 045 thru 155 series a variable speed 4-way multipoise induced combustion gas furnace

Advertisement

Unit
Operating Mode
Size
036070
†† Low Heat
High Heat
†† 1-1/2-Ton Cooling
†† 2-Ton A/C Cooling
2-1/2-Ton A/C Cooling
3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
Maximum
048090
Low Heat
High Heat
†† 1-1/2-Ton A/C Cooling
†† 2-Ton A/C Cooling
2-1/2-Ton A/C Cooling
3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
4-Ton A/C Cooling
Maximum
060110***
Low Heat
High Heat
†† 2-Ton A/C Cooling
†† 2-1/2-Ton A/C Cooling
†† 3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
4-Ton A/C Cooling
5-Ton A/C Cooling
6-Ton A/C Cooling
Maximum
066135
Low Heat
High Heat
†† 2-Ton A/C Cooling
†† 2-1/2-Ton A/C Cooling
†† 3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
4-Ton A/C Cooling
5-Ton A/C Cooling
6-Ton A/C Cooling
Maximum
066155
Low Heat
High Heat
†† 2-Ton A/C Cooling
†† 2-1/2-Ton A/C Cooling
†† 3-Ton A/C Cooling
3-1/2-Ton A/C Cooling
4-Ton A/C Cooling
5-Ton A/C Cooling
6-Ton A/C Cooling
Maximum
*
Actual external static pressure (ESP) can be determined by using the fan laws (CFM
a system with 1180 CFM at 0.5 ESP would operate at cooling airflow of 1050 CFM at 0.4 ESP and low-heating airflow
of 735 CFM at 0.19 ESP.
"Comfort mode" airflow values are shown in parenthesis. "Comfort mode" airflow is selected when the low-heat rise
adjustment switch (SW1-3) is OFF and the comfort/efficiency switch (SW1-4) is ON. Furnaces are shipped in this
configuration.
Ductwork must be sized for high-heating CFM within the operational range of ESP.
††
Operation within the blank areas of the chart is not recommended because high-heat operation will be above 1.0 ESP.
***
All airflows on 110 size furnace are 5% less on side return only installations.
AIR DELIVERY - CFM (Bottom Return With Filter)*
CFM Airflow
External Static
Setting
Pressure Range*
735 (615)†
0-0.50
1180 (1060)†
0-1.0
525
0-0.50‡
700
0-0.50‡
875
0-1.0‡
1050
0-1.0‡
1225
0-1.0
1400
0-1.0
985 (825)†
0-1.0
1210 (1090)†
0-1.0
525
0-0.50‡
700
0-0.50‡
875
0-1.0‡
1050
0-1.0‡
1225
0-1.0‡
1400
0-1.0
1600
0-1.0
1320 (1110)†
0-1.0
1475 (1330)†
0-1.0
700
0-0.50‡
875
0-0.50‡
1050
0-0.50‡
1225
0-1.0‡
1400
0-1.0‡
1750
0-1.0‡
2100
0-1.0
2200
0-1.0
1700 (1430)†
0-1.0
1915 (1725)†
0-1.0
700
0-0.50‡
875
0-0.50‡
1050
0-0.50‡
1225
0-1.0‡
1400
0-1.0‡
1750
0-1.0‡
2100
0-1.0
2200
0-1.0
1715 (1440)†
0-1.0
1970 (1775)†
0-1.0
700
0-0.50‡
875
0-0.50‡
1050
0-0.50‡
1225
0-1.0‡
1400
0-1.0‡
1750
0-1.0‡
2100
0-1.0
2200
0-1.0
External Static Pressure (ESP)
0.1
0.2
0.3
0.4
735
735
735
1160 1165 1175 1180 1180 1180 1180 1180 1180 1175
525
525
525
700
700
700
875
875
875
1050 1050 1050 1050 1050 1050 1050 1050 1045 1035
1205 1215 1225 1225 1225 1225 1225 1225 1225 1210
1395 1400 1400 1400 1400 1400 1400 1385 1360 1310
950
970
985
1190 1205 1210 1210 1210 1210 1210 1210 1210 1200
525
525
525
690
695
700
830
855
875
1005 1025 1040 1050 1050 1050 1050 1050 1050 1050
1205 1220 1215 1225 1225 1225 1225 1225 1225 1220
1370 1385 1395 1400 1400 1400 1400 1400 1400 1380
1565 1580 1585 1595 1600 1600 1560 1520 1480 1430
1275 1295 1315 1320 1320 1320 1320 1320 1320 1315
1460 1465 1475 1475 1475 1475 1475 1475 1465 1465
700
700
700
860
875
865
1050 1050 1045 1050 1050
1185 1195 1215 1225 1225 1225 1225 1225 1225 1225
1385 1395 1400 1400 1400 1400 1400 1400 1400 1400
1710 1730 1745 1745 1750 1750 1750 1750 1745 1740
2090 2100 2100 2100 2095 2085 2065 2045 2020 1990
2200 2200 2200 2190 2185 2175 2155 2130 2085 2015
1700 1700 1700 1700 1700 1695 1700 1695 1685 1670
1900 1905 1915 1915 1915 1915 1915 1915 1915 1915
700
700
700
870
870
865
1010 1030 1050 1050 1050
1155 1180 1200 1210 1220 1225 1225 1225 1225 1225
1395 1400 1400 1400 1400 1400 1400 1390 1375 1355
1740 1750 1750 1750 1735 1740 1735 1730 1715 1700
2075 2085 2090 2100 2100 2100 2090 2080 2055 2025
2180 2195 2200 2200 2200 2200 2185 2165 2140 2095
1715 1715 1715 1715 1715 1705 1710 1705 1705 1695
1955 1965 1965 1970 1970 1970 1970 1970 1970 1960
700
700
700
865
875
875
1015 1020 1035 1045 1050
1160 1185 1215 1225 1225 1225 1225 1225 1225 1225
1385 1400 1400 1400 1400 1400 1395 1395 1380 1360
1745 1750 1750 1750 1745 1740 1745 1745 1740 1735
2055 2070 2080 2085 2095 2100 2100 2100 2090 2065
2175 2190 2200 2200 2200 2200 2200 2200 2180 2160
2
proportional to ESP); such as,
-8-
0.5
0.6
0.7
0.8
AIRFLOW (CFM)
735
725
525
510
695
685
875
875
875
865
855
985
985
985
985
985
525
500
700
690
875
875
875
870
865
685
660
855
840
700
665
865
865
700
680
865
865
0.9
1.0
845
840
985
980
850
820