Performing An Emergency Shutdown; Restoring Power After An Unexpected Shutdown - IBM System Storage DS5020 Installation, User's, And Maintenance Manual

Storage subsystem
Hide thumbs Also See for System Storage DS5020:
Table of Contents

Advertisement

10. Remove (unplug) all of the power cords from the DS5020 power supply
11. After you perform the necessary maintenance procedures, turn on the power

Performing an emergency shutdown

Attention:
conditions, or other hazardous circumstances. If a power outage or emergency
situation occurs, always turn off all power switches on all computing equipment.
This helps to safeguard your equipment from potential damage due to electrical
surges when power is restored. If the storage subsystem loses power unexpectedly,
it might be due to a hardware failure in the power system or in the midplane.
Complete the following steps to shut down the system during an emergency:
1. If you have time, stop all I/O activity to the storage subsystem by shutting down
2. Check the LEDs. Make note of any Needs Attention LEDs that are on so you
3. Turn off all power supply switches, starting with the DS5020 storage subsystem

Restoring power after an unexpected shutdown

Use the following procedure to restore power to the storage subsystem in a
configuration after an unplanned shutdown.
114
IBM System Storage DS5020 Storage Subsystem: Installation, User's, and Maintenance Guide
9. Turn off both power switches on the back of each storage expansion enclosure
in the configuration.
CAUTION:
The power switch on the power supply and fan unit does not turn off the
electrical current supplied to the device. The DS5020 storage subsystem
might also have more than one connection to ac power. To remove all
electrical current from the device, ensure that all ac power cords are
disconnected from the power supply and fan unit ac input connectors.
connectors.
using the procedure in "Turning on the storage subsystem" on page 97.
Emergency situations might include fire, flood, extreme weather
the host or disconnecting the storage subsystem logical drives through the host.
can correct the problem when you turn on the power again.
first, and followed by the storage expansion enclosures. Then, unplug the power
cables from the storage subsystem.
CAUTION:
This unit has more than one power source. To remove all power from the
unit, all MAINS must be disconnected.
CAUTION:
The power switch on the power supply and fan unit does not turn off the
electrical current supplied to the device. The DS5020 storage subsystem
might also have more than one connection to ac power. To remove all
electrical current from the device, ensure that all power cords are
disconnected from the power supply and fan unit input connectors.