programmer interface, 3-pin black plug
The black three pin port is provided for personal computer programming of the unit. When using the DEI Bitwriter
(P/N 998T) or optional PC Interface module (P/N 996T) it is possible to configure any and all of the program-
mable functions using an IBM-compatible personal computer. For more information please refer to the guide
packaged with the programmer. This port can also be used to interface the Valet® Car Com (DEI P/N 820T) with
the security system.

shock sensor harness, 4-pin connector

GREEN (-) multiplex input
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and report zone four. If installing an optional DEI® dual stage sensor, connect to the
green wire as shown below. The diagram below eliminates the need for diodes to isolate the sensors, as well as
providing a separate zone for each sensor.
Diagram for adding optional DEI
BLUE (-) multiplex input
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and report zone two.
RED (+) 12V constant and BLACK (-) ground
Do not use these for anything besides the plug-in shock sensor.
© 1999 Directed Electronics, Inc. Vista, CA
®
dual stage sensor to green wire (zone 4)