Calculation values for calculating cross-section to EN 13384
Flue gas mass flow at maximum/minimum nominal output
Flue gas temperature 176/140 °F (80/60 °C) at maximum/minimum
nominal heat input
Flue gas temperature 104/86 °F (40/30 °C) at maximum/minimum
nominal heat input
CO
at max. nominal output
2
CO
at minimum nominal output
2
Condensate
Max. condensate quantity (t
R
pH level, approx.
General
Voltage
Frequency
Max. power consumption (central heating mode)
Max. power consumption (Stand-by)
Noise level
Maximum supply temperature
Max. permissible operating pressure (P
Permissible ambient temperature
Nominal water capacity (heating)
Weight (without packaging)
Dimensions, W x H x D
Tab. 7
Technical data heating boiler ZBR42-3A...
Copyright (optional information)
= 86 °F (30 °C))
) heating
MS
Information about the appliance | 27
Unit
NG
gps
18.0/4.5
°F ( °C)
171/135 (77/57)
°F ( °C)
133/91 (56/33)
%
9.4
%
8.6
gph (l/h)
0.9 (3.5)
4.8
VAC
120
Hz
60
W
205
W
< 6
dB(A)
≤ 45
°F ( °C)
194 (90)
psi (bar)
30 (2.07)
°F ( °C)
32 - 122 (0 - 50)
Gal (L)
0.925 (3.5)
lbs. (kg)
103.6 (47)
inch
17-21/64" × 33-15/32" × 13-57/64"
(mm)
LPG (propane)
17.5/5.6
171/135 (77/57)
133/91 (56/33)
11.0
10.4
0.9 (3.5)
4.8
120
60
205
< 6
≤ 45
194 (90)
30 (2.07)
32 - 122 (0 - 50)
0.925 (3.5)
103.6 (47)
(440 × 850 × 353)