7.

Installation

Securing to the wall

• The weight of the device will be applied to the wall. If the strength of the wall is not suffi-
cient, reinforcement must be done to prevent the transfer of vibration.
• Do not drop or apply unnecessary force to the device when installing. Internal parts may
be damaged and may become highly dangerous.
Be sure to do
• Install the unit on a vertical wall and ensure that it is level.
Item
• When installing with bare hands, take caution to
not inflict injury.
• Be careful not to hit electrical wiring, gas, or water
piping while drilling holes.
1. Drill a single screw hole, making sure to hit a stud.
2. Insert and tighten the screw and hang the unit by
the upper wall mounting bracket.
3. Determine the positions for the remaining four screws
(two for the top bracket and two for the bottom), and
remove the unit.
4. Drill holes for the remaining four screws.
5. Hang the unit again by the first screw, and then
insert and tighten the remaining four screws.
6. Take waterproofing measures so that water does
not enter the building from screws mounting the
device.
• Make sure the unit is installed securely so that it will
not fall or move due to vibrations or earthquakes.
• Adjust the dip switches as illustrated in the table to
the right if this water heater is installed at an altitude
of 2000 ft. (610m) or higher.
• Disconnect power to the water heater before chang-
ing the dip switches. Failure to perform this step will
result in a "73" code displayed on the remote control-
ler and a cease in operation. If this occurs, discon-
nect, then reconnect power to the water heater to
reset the system.
Note : Please refer to page 20 for the location of the
dip switch bank.
Check
CAUTION
Illustration
Location of Screw Hole
Mounting Bracket
(upper)
Locating Screw Holes
Tapping Screw
* Do not change any other dipswitches.
* High elevation adjustment.
5
6
Standard
2,000 ft (610m)
4,000 ft (1,220m)
6,000 ft (1,830m)
ON=
OFF=
9