Quick Connect Multi System Installation

• The Quick Connect Multi System allows the installation of two units together utilizing only the Quick
Connect Cord.
The Quick Connect Cord is 6 ft.(2m) long. Install the units 2-18" (50 - 457mm) apart from each
other to ensure the cord will be able to reach between the units. (See Typical Plumbing diagram).
(If the distance between the two units is too great, not only will the cord not be able to reach,
but the water temperature may also become unstable because of the difference in pipe length
between the two units).

System Diagram

Quick Connect
Cord
Cord
Connector
Typical Plumbing
Make this distance as short as possible.
* The hot water temperature will
become unstable as the pipe
length increases.
• Insulate the hot water piping to prevent heat loss. Insulate and apply heating materials to the
cold water supply piping to prevent heat loss and freezing of pipes when exposed to excessively
cold temperatures.
Cord
Connector
Terminal Block
Remote Controller Cord
Distance at center: 20.3 - 36.3 in. (515 - 922mm)
2 - 18 in. (50 - 457mm)
Union
Quick Connect
Union
cord
Pressure
Relief
Union
Valve
Shutoff
Gas Valve
Valve
Shutoff Valve
Leave enough clearance around the plumbing to
apply insulation. It will be necessary to add
bends to the piping to ensure that this clearance
is available.
* When connecting two units, use only a
single remote controller.
Note: Connect the remote
Remote Controller
Gas Supply Piping
G
Cold Water Supply
Hot Water
Distance on sides
The backflow preventer is
put up before it diverges.
controller to only one
of the units.
Size the piping to allow for the
maximum flow rates of the units.
Hot Water
Cold Water
Shutoff Valve