Advertisement

Quick Links

User Manual
IR Sensor
SIA-0120/0120D

Important Safety Instructions

1.
Read these instructions.
2.
Keep these instructions.
3.
Heed all warnings.
4.
Follow all instructions.
5.
Do not use this apparatus near water.
6.
Clean only with dry cloth.
7.
Do not block any ventilation openings, Install in accordance with the manufacturer's instructions.
8.
Do not install near any heat sources such as radiators, heat reaisters, stoves, or other apparatus (including amplifi ers)
that produce heat.
9.
Do not defeat the safety purpose of the polarized or grounding-type plug, A polarized plug has two blades with one wider
than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong
are provided for your safety, If the provided plug does not fi t into your outlet, consult an electrician for replacement of the
obsolete outlet.
10.
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.
11.
Only use attachments/ accessories specifi ed by the manufacturer.
12.
Use only with the cart, stand, tripod, bracket, or table specifi ed by the manufacturer, or sold with
the apparatus. When a cart is used. Use caution when moving the cart/apparatus combination to
avoid injury from tip-over.
13.
Unplug this apparatus during lighting storms or when unused for long periods of time.
14.
Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way,
such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
English _1

Advertisement

Table of Contents
loading

Summary of Contents for Samsung SIA-0120D

  • Page 1: Important Safety Instructions

    User Manual IR Sensor SIA-0120/0120D Important Safety Instructions Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water. Clean only with dry cloth. Do not block any ventilation openings, Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat reaisters, stoves, or other apparatus (including amplifi...
  • Page 2: Explanation Of Graphical Symbols

    WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS PROCUCT TO RAIN OR MOISTURE. DO NOT INSERT ANY METALLIC OBJECT THROUGH THE VENTILATION GRILLS OR OTHER OPENNINGS ON THE EQUIPMENT. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus CAUTION CAUTION...
  • Page 3 When used outside of the U.S., it may be used HAR code with fittings of an approved agency is employed. CAUTION These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
  • Page 4: What's Included

    IR Sensor at a Glance Cover Receiver Transmitter Bracket Temper Terminal Monitor Jack Good LED Channel Switch Power LED Response Time Control Wheel Alarm LED Sight Window Lens Vertical Angle Adjustable Screw What’s Included Steel Bracket (x2) Screw (x4) Film User Manual/Warranty Card U-shaped Bracket x2 (optional) English _4...
  • Page 5: Installation Instructions

    Installation Instructions For best performance, you should consider the followings when placing, installing and keeping the product at a distance from the object. • Do not expose it to a place where its light projector or light receiver is affected by a direct strong light such as sunlight or headlight.
  • Page 6  Put the cover as original. Pole external diameter: Φ38~Φ46  Channel Setting (SIA-0120D) To prevent misalarming due to possible frequency interference between two or more sensors in one place, set the channel respectively. <1 CH> <2 CH>...
  • Page 7 Adjusting the response speed You can adjust the response time by turning the response time control wheel left or right. Turning it left will speed up the response time; turn it right to slow down the time.  The factory default is set to 250 msec. •...
  • Page 8 You can use the tester to measure the DC voltage and refi ne your adjustment. Check the output voltage of the tester and close the cover. Output Voltage Optical Axis Status SIA-0120 SIA-0120D Good 3.0V or higher 2.2V or higher To be adjusted 2.9V or lower...
  • Page 9: Troubleshooting

    Troubleshooting Problem Reason Action The power indicator of the Power is not supplied. Apply the power. transmitter does not turn Loose connection or short-circuited Check if the cables are properly connected. Even if I block the infrared Power is not supplied. Turn on the sensor.
  • Page 10 Specifi cations & Appearance Specifi cations Item Description Model SIA-0120 SIA-0120D Work Range Outdoor 120m Detection System NIR Blocking System (Twin Beams) IR Light IR LED Response Time 50 ~ 500 ms Power Voltage DC 12V(±15%) Alarm: 1.8V or lower Alarm: 1.0V or lower...
  • Page 11: Correct Disposal Of This Product

    Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in the European Union and other European countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB cable) should not be disposed of with other household waste at the end of their working life.

This manual is also suitable for:

Sia-0120

Table of Contents