Dive Numbering Shown During Dive Planning - Suunto D6i User Manual

Hide thumbs Also See for D6i:
Table of Contents

Advertisement

any calculated residual nitrogen
all dive history for the past four days
The no-decompression times given for different depths will therefore be shorter than
before your first "fresh" dive.
You can exit the DIVE PLANNING mode by pressing the MODE button.
NOTE
Higher Altitude and conservative Personal Adjustment settings will shorten the no-
decompression time limits. These limits at different Altitude and Personal Adjustment
setting selections are explained in Section 5.9.4. Diving at altitude and in Section 5.9.5.
Personal adjustments.

7.5.1. Dive numbering shown during dive planning

Dives belong to the same repetitive dive series if the instrument was still counting
down the no-fly time at the beginning of the dive.
The surface interval must be at least five (5) minutes for a dive to be considered a
repetitive dive. Otherwise, it is considered a continuation of the same dive. The dive
number will not change and the dive time will continue where it left off. (Refer also to
Section 7.2. Dive numbering ).
The DIVE PLANNING mode is disabled in GAUGE mode and
in Error mode (see Section 5.6. Error conditions).
The DIVE PLANNING mode calculates no-decompression
times for Mix1 only. If an additional mix is enabled in the Nitrox
mode, it does not affect the calculations in (PLAN NoDec)
mode.