Acoustic Data; Acoustic Data - LG LC247HV Engineering Manual

Single-zone four-way ceiling-cassette system
Hide thumbs Also See for LC247HV:
Table of Contents

Advertisement

Figure 6: Four-Way Ceiling Cassette Outdoor Unit Sound Pressure
Level Measurement Location.
D
3.3 ft.
Figure 7: Four-Way Ceiling Cassette Outdoor Unit Sound Pressure Level Diagrams.
LUU187HV, LUU247HV
80
▲ Cooling
70
60
50
40
30
20
Approximate
Hearing
Threshold
10
63
125
250
500
1000
2000 4000
Octave Band Center Frequency (Hz)
4.9 ft.
LUU367HV, LUU427HV
80
Heating
70
NC-65
60
NC-60
NC-55
50
NC-50
NC-45
40
NC-40
NC-35
30
NC-30
NC-25
20
NC-20
Approximate
Hearing
Threshold
NC-15
10
8000
63
125
Octave Band Center Frequency (Hz)
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
• Measurements taken with no attenuation and units operating at full
load normal operating condition.
• Sound level will vary depending on a range of factors such as
construction (acoustic absorption coefficient) of particular area in
which the equipment is installed.
• Sound power levels are measured in dB(A)±3.
• Tested in anechoic chamber per ISO Standard 3745.
Table 4: Four-Way Ceiling Cassette Outdoor Unit Sound
Pressure Levels (dB[A]).
Model
LUU187HV
LUU247HV
LUU367HV
LUU427HV
▲ Cooling
Heating
NC-65
NC-60
NC-55
NC-50
NC-45
NC-40
NC-35
NC-30
NC-25
NC-20
NC-15
250
500
1000
2000 4000
8000

aCouStiC Data

outdoor units
Sound Pressure Levels (dB[A])
Cooling
Heating
48
48
52
52
Four-Way caSSette | 15
52
52
54
54