T T r r o o u u b b l l e e s s h h o o o o t t i i n n g g
P P r r o o b b l l e e m m
Ice maker is not producing Ice maker arm is up
ice.
Water filter indicator
light is red
Refrigerator is leaking
water
Ice forms in inlet
tube to ice maker
Water flow is slower than
normal
.
Dispenser water is not
cold
Water appears cloudy
Particles in water and/or
ice cubes
* * M M a a n n u u f f a a c c t t u u r r e e r r i i s s n n o o t t r r e e s s p p o o n n s s i i b b l l e e f f o o r r p p r r o o p p e e r r t t y y d d a a m m a a g g e e d d u u e e t t o o i i m m p p r r o o p p e e r r i i n n s s t t a a l l l l a a t t i i o o n n o o r r w w a a t t e e r r c c o o n n n n e e c c t t i i o o n n . .
P P o o s s s s i i b b l l e e C C a a u u s s e e
Water supply is not reaching water valve.
Copper tubing has kinks
Water pressure is too low
Check freezer tempertaure
Ice bin is not installed properly
Improper water valve was installed.
Water filter needs to be replaced.
Filter indicator sensor needs to be reset
Plastic tubing was used for water connection
Improper water valve installed
Water pressure is low
Improper water valve installed.
Copper tubing has kinks
Saddle valve is not open completely.
Freezer temperature is too high
Water pressure is low
Saddle valve is not open completely.
Improper water valve installed.
Copper tubing has kinks
Water filter needs to be changed
Refrigerator has been recently installed.
Water supply in holding tank has been used.
Air or bubbles in water.
Carbon dust from water filter cartridge
Concentration of minerals in water will
form particles when water becomes frozen
and melts.
W W h h a a t t T T o o D D o o
Confirm ice maker arm is down. See Automatic Ice Maker
instructions in use and care
See Connecting the Water Supply instructions.
Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Low water pressure must be between 35 to 100 pounds per
square inch to function properly. A minimum pressure of 35
pounds per square inches recommended for refrigerators with
water filters.
See Temperature Controls in use and care manual to adjust
controls. Freezer must be between 0
See Ice and Water instructions in use and care manual.
See Connecting the Water Supply instructions. Self-piercing and
3/16" saddle valves cause low water pressure and may clog the
line over time.*
If filter is not available, replace with bypass filter. See Water
Filter instructions in use and care manual.
See Filter Status Indicator Light in use and care manual.
The manufacturer recommends using copper tubing. Plastic
is less durable and can cause leakage*.
Check water connection procedure in installation instructions.
Self piercing and 3/16" saddle valves cause low water pressure
and may clog the line over time.*
Water pressure must be between 35 - 100 pounds per square
inch. A minimum pressure of 35 pounds per square inch is
recommended for refrigerators with water filters.
Check water connection procedure in installation instructions.
Self piercing and 3/16" saddle valves cause low water pressure
and may clog the line over time.*
Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Open saddle valve completely.
Adjust freezer controls. Freezer is recommended to be
approximately 0
F (-18
o
Water pressure must be between 35 - 100 pounds per square
inch. A minimum pressure of 35 pounds per square inch is
recommended for refrigerators with water filters/
Open saddle valve completely.
Check water connection procedure in installation instructions.
Self piercing and 3/16" saddle valves cause low water pressure
and may clog the line over time.*
Turn off water supply and remove kinks. If kinks cannot be
removed, replace tubing.
Change water filter. See use and care manual.
Allow approximately 12 hours for water in holding tank to chill.
This is normal when first using the dispenser and will disappear
with use.
Initial water ejected through cartridge may contain harmless
carbon dust flushed from cartridge. Will disappear after first few
uses.
Particles are not harmful and naturally occur in water supplies.
11
o
- 2
o
F (-18
o
to -17
C)/
o
o
C).

Advertisement

loading

This manual is also suitable for:

Ddsf