FILLING AND BLEEDING THE COOLING CIRCUIT
HFX-KFV-NFU
Tools
[1] Filling cylinder
[2] Adaptor for filling cylinder
[3] Pliers for removing-refitting elastic clips
Draining.
Perform the operation with the engine cold.
Remove the air filter housing.
Open the expansion chamber cap.
Uncouple bottom hose (1), using tool [3] and bottom hose (2) of the radiator.
8HX
Open :
The bleed screw on the coolant outlet housing.
The bleed screw on the heater matrix.
The cylinder block drain plug.
Allow the coolant to flow out.
Before any refilling, rinse the cooling circuit with clean water.
Couple the bottom hose (1) and (2).
B1BP2LUC B1GP0AQD
: 4520-T
: 4222-T.
: 9029-T
96