2. OUTDOOR UNIT INSTALLATION

2-1. INSTALLING THE UNIT

• Do not use the drain socket and the drain cap in the cold region.
Make the setting
depth deeper.
2-2. CONNECTING WIRES FOR OUTDOOR UNIT
• Be sure to use special circuits for room air conditioner.
• Wiring work should be based on applicable technical standards.
• Wiring connections should be made following the diagram.
OUTDOOR UNIT
Compressor
Control voltage
against unit with screws.
minal block.
is completed.
Connecting order
• Connect the terminal block in order,
from the A, B and C unit side.
Fix here with
M10 bolts.
Make with wider.
ELECTRICAL SPECIFICATIONS
MXZ-3A30NA
20
15
0.93
11
15
Indoor unit-Outdoor unit : DC12-24V
-
Terminal block for
indoor/outdoor unit
Anchor leg
500
Anchor both length
Anchor both pitch
MXZ-4A36NA
208/230, 1, 60
Service panel
20
19
0.93
14.4
15
4A36NA