1-6. INSTALLATION DIAGRAM

MXZ-3A30NA
More than
100 mm
Open as a rule
both sides and top are open
200
1-7. MOUNTING ARRANGEMENT OF DRAIN SOCKET
1 Choose one hole to discharge drain and install the drain socket to the hole.
2 Close the rest of the holes with the drain caps.
Note:
Do not use the drain socket and the drain cap in the cold region.
4
no gap.
When the piping is to be at-
tached to a wall containing metals
between the wall and the piping
or wrap 7 to 8 turns of insulation
Open as a rule
More than 500 mm
To use existing piping, perform
COOL operation for 30 minutes
and both sides are open
and pump down before removing
the old air conditioner. Remake
for new refrigerant.
More than
More than
obstacles to both sides
Outdoor unit installation
2-U-shape notched holes
Air in
Air out
PARTS TO BE PROVIDED AT YOUR SITE
Indoor/outdoor unit connecting wire*
-
Wall hole cover
Piping tape
Extension drain hose
(or soft PVC hose, 15 mm (19/32
Refrigeration oil
Wall hole sleeve
inner diameter or hard PVC pipe
VP25 for drain socket
* Note:
from the TV antenna wire.
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1
1
-