Part Iii Specifications - Lavry DA924 Operation Manual

High resolution digital to analog converter
Table of Contents

Advertisement

Operations Manual
P a r t I I I : S p e c i f i c a t i o n s
Noise
Distortion
Sample rate
Crystal lock™ tracking
Channel separation
Flatness response
Phase linearity
Digital inputs
Analog outputs
Warm-up and initial calibration 10 minutes maximum
Hardware
Options
-110dBFS rms, 130dBFS peak spurious response
1kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
1kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
10kHz tone at -1dBFS: .0009%FS peak harmonic amplitude
10kHz tone at -60dBFS: .00009%FS peak harmonic amplitude
96kHx, 88.1kHz, 48kHz, 44.1kHz at +/- 150ppm lock range
40-50kHz wide lock mode (varispeed)
1ppm / 15 seconds
-100dBFs at 1KHz
+/- .05dB (10Hz -20KHz)
2 degrees (10Hz - 20 KHz)
two AES/EBU, 110 Ohm, transformer isolated
one Consumer, 75 Ohm, transformer isolated
AES/EBU balanced 22dBuFS into 600 ohms Max
AES/EBU unbalanced 16dBuFS into 600 ohms Max
Consumer outputs 8.5dBuFS into 10k ohms Max
19 inch rack mount, 1U high
115V 60Hz or 220V 50Hz, 20 Watts
Removable interface for future I/O hardware interface
12dBuFS Min
6dBuFS Min
-2.5dBuFS Min
DA924
13

Advertisement

Table of Contents
loading

Table of Contents