Range Hood Installation - Electrolux E30WV60PPS Installation, Use & Care Manual

30”(76.2 cm) and 36”(91.4 cm) range hood
Hide thumbs Also See for E30WV60PPS:
Table of Contents

Advertisement

Range Hood Installation

8
Installation
Installation - Ducting version
After having chosen the vent option, proceed as
follows:
Prepare duct and conduit cut outs as needed.
If possible, disconnect and move freestanding
or slide-in range from cabinet opening to provide
easier access to rear wall. Otherwise put a thick,
protective covering over countertop, cooktop or
range to protect from damage and debris. Select
a flat surface for assembling the unit.
Cover that surface with a protective covering and
place all canopy hood parts and hardware in it.
Determine and mark the centerline on the wall
where the canopy hood will be installed.
Select a mounting height comfortable for the user
and mark on wall.
Prepare duct and conduit cut outs as needed.
Remove the duct knockouts using a flat blade
screwdriver and a small hammer.
Use the screwdriver by knocking out the pannel in
similar fashion to a scalpel.
Take care of sharp edges.
Attach exhaust adaptor/damper over knockout open-
ing with three exhaust adaptor screws. Make sure
damper pivot is nearest to top/back edge of hood.
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed
up to 1 inch on either side of the hood center to ac-
commodate offcenter ductwork. In extreme offcenter
installations, one end of the duct connector may need
to be trimmed to clear the electrical cable clamp.
Vertical
discharge
Horizontal
discharge
Exhaust
transition/damper
Pivot
Pivot
Mark holes
Select the vent option that your installation will require
and proceed to that section:
Outside top exhaust
(Vertical duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
30" Model: 2-7/8"
36" Model: 5-3/4"
Cabinet front
13/32"
5"
5"
7-1/2"
7-7/8"
Vertical duct
access hole
2-1/2"
Electrical access hole
Center line
(in cabinet bottom)
Outside rear exhaust
(Horizontal duct– 3
"x 10" Rectangular)
1
4
Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
Wood shims (recessed
bottom cabinets only)
Cabinet front
2-11/32"
Horizontal duct
access hole
5"
30" Model: 4-15/32"
36" Model: 7"
Electrical
30" Model: 6-3/8"
access hole
36" Model: 8-7/8"
(in wall)
Center line
Top/back
edge
Top/back
edge
Exhaust
transition/damper
Hood mounting
screws (4)
Wood shims (recessed
bottom cabinets only)
3-1/4"
5/8"
21/32"
3-1/4"
Hood mounting
5"
screws (4)
Cabinet
bottom
13/32"