Q270 Condenser Fan Motor Replacement

Access to remove, clean or replace the condenser fan/
motor can be obtained by performing the following:
1. Disconnect electrical power to the ice machine at
the electrical service disconnect.
2. Remove the screws that secure the condenser to
the cabinet and the base to the cabinet.
3. Slide the base forward until contact is made with
the stop screw (approximately 2.5" [6.3 cm]).
Do not move base p ast the st op scre w, t ubing
damage could result.
4. Remove right hand screw securing condenser to
base.
5. Pivot condenser forward to obtain 5" (12.7 cm)
between the cabinet and condenser shroud. Take
care not to kink refrigeration tubing.
REMOVE THREE
SCREWS AND
PULL BASE
FORWARD TO
STOP SCREW.
Accessing the Condenser Fan Motor
196
! Caution
2.5" (6.3 CM) TO
STOP SCREW
Part Number 80-01111-9 7/10
5" (12.7 CM)
CLEARANCE
AFTER
PIVOTING
CONDENSER
REMOVE SCREW AND
PIVOT CONDENSER TO
OBTAIN 5" (12.7 CM)
CLEARANCE BETWEEN
CABINET AND
CONDENSER SHROUD.
PT1295A