Viewing And Changing The Model Number - GE AvantaPure Operation Manual

Avantapure professional series water treatment system
Table of Contents

Advertisement

Scrolling
Display
Select
MODEL
NUMBER
Time of Day
Day xx
Regeneration
Time
Avantapure 268
WARNING: Only the model numbers in
Table 1 are to be used. Using a model
number that is not in Table 1 will cause
undesirable performance. If the
programmed model number needs to be changed follow
the steps below to select a valid model.
Viewing and Changing the Model
Number
Viewing the Model Number
Press and hold the SET and DOWN buttons simultaneously
until the display blanks out. Release buttons.
The Model Number will be displayed. Proceed to the next
step to change the Model Number. Note: The control will
revert back to the service display if no buttons are pushed
within 30 seconds
To Change The Model Number
Press and hold the SET button until 0 is displayed
Release button.
A flashing 11 will now be displayed on the screen, which is
a default model number.
Press the UP or DOWN button until the desired model
number is displayed (See Table 1). *
Press and release the SET button to save the desired model
number.
Time of day will scroll and time will be flashing.
*The Model Number setting is very important. The
Buttons to
Description
Press
1. Default is 11
press
or
Must select model from table
then
2. Time of Day
Set to time of day. Includes PM
or
press
monitor. The time will flash.
then
Default is a 12 hr clock
press
3. Day of Week
or
then
Set to actual day of the week.
press
4. Time of Regeneration
press
Set to desired time of
or
then
regeneration. The time will flash.
press
Programming is complete.
Service Display
Scrolling name and valve model . Time
with flashing colon.
Capacity remaining shown as 1 to 5 bars.
22
Range
The range is 1-99 however,
only the model selections in
the table above are valid
selections.
12 or 24
SU, MO, TU, WE, TH, FR, SA
Full 24 hours.
Increments of 1 minute.
AvantaPure controller software includes additional Model
Numbers that operate other AvantaPure valve types. If the
Model number is set incorrectly an ERROR 3 could be
displayed when advancing the valve through the
regeneration cycles. The valve will not function properly.
The control Model Number must be selected from Table 1
in this service manual.