Samsung SID-370 User Manual page 18

High resolution 37x zoom color dome camera
Table of Contents

Advertisement

Operating Your Camera
Notes
• W hen using a Video Auto Iris Lens, if you set the lens level to low, automatic switching
between Color and Black & White may not occur.
• Y ou cannot control the DAY/NIGHT menu when AGC in the EXPOSURE menu is 'OFF'.
At this time, the exchange between DAY mode and NIGHT mode operates as like selecting
'COLOR' mode.
• T he OSD key does not work for 3 seconds when switching to Color or B/W, to ensure
stable camera operation.
• T he camera may focus less well under infrared illumination than under normal illumination.
• S ince the camera may not focus as well under infrared illumination at night as it does
under normal illumination, install an Extra-low Dispersion Lens to obtain sharp pictures.
• T he brightness of illumination is changeable by installed environment.
DIS : The DIS mode can compensate for vibration of the camera.
SPECIAL SETUP
PRIVACY
DAY/NIGHT
DIS
COMM ADJ
Notes
• W hen DIS is operating, D-ZOOM does not operate.
COMM ADJ (Communication Adjustment) :
This function sets up the camera communication
status when controlling the camera through an
external control device.
W hen the SPECIAL menu screen is displayed, moving up or down direction of
1
Function Setup Switch so that the arrow indicates 'COMM ADJ'.
Set up the mode moving the 4 direction of Function Setup Switch.
2
34
COLOR CCD CAMERA
OFF
COLOR
OFF
COMMUNICATION SETUP
STW
▶PROTOCOL
CAM ID
1
|
|||||||||||||||||||||||||
BAUD RATE
9600
UART MODE
8-N-1
TERMINATON
OFF
RET PKT
DISABLE
END
User's Manual (SID-370)
• CAM ID
: Determines the camera's identification number
(between 0 and 255).
• Protocol
: Select the communication PROTOCOL. (STW/PELCO-D/PELCO-P/
BOSCH/HONEYWELL/VICON/AD/SEC/PANASONIC)
• BAUD RATE
: You can select 2400/4800/9600/19200/38400/57600/115200 bps.
• UART MODE : You can select NONE, EVEN or ODD for the parity bits.
• TERMINATION : Functi on that sets the resistance at the end of RS-485
communications.
✽ Setting Termination Resistance.
In order to prevent signal reduction, the termination resistance of the 2 end units,
which are the distant paths for camera and controller to be connected on the RS485
interface, should be connected.
As the termination resistance is built in the camera, whether to make the termination
resistance valid or invalid is selected with the TERMINATION.
See the connection diagram for determining to which device the termination
resistance will be connected to.
Set up the termination resistance in the dark products.
The installation distance of the product for the termination resistance setting should
be less than 1.2 Km. (Maximum cable length is 1.2 Km according to the RS-485
standards.)