SPECIFICATIONS

CSG3924PT, VRL24PT, VRL30PT
• 10,000/40,000 Btu (Variable)
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 7.4" W.C.
• Inlet Gas Pressure (in. of water): Maximum 14" W.C., Minimum* 11" W.C.
• Certified Standards: Z21.11.2-2007
CSG3924NT, VRL24NT, VRL30NT
• 10,000/40,000 Btu (Variable)
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water): Maximum 10.5" W.C., Minimum* 5" W.C.
• Certified Standards: Z21.11.2-2007
CSG3924PR, VRL24PR, VRL30PR
• 10,000/40,000 Btu (Variable)
• Type Gas: Propane/LP
• Ignition: Piezo
• Manifold Pressure: 8" W.C.
• Inlet Gas Pressure (in. of water): Maximum 14" W.C., Minimum* 11" W.C.
• Certified Standards: Z21.11.2-2007, Z21.60-1996, CGA2.26-M96
CSG3924NR, VRL24NR, VRL30NR
• 10,000/40,000 Btu (Variable)
• Type Gas: Natural
• Ignition: Piezo
• Manifold Pressure: 3" W.C.
• Inlet Gas Pressure (in. of water): Maximum 10.5" W.C., Minimum* 5" W.C.
• Certified Standards: Z21.11.2-2007, Z21.60-1996, CGA2.26-M96
* For purpose of input adjustment