5. Turn control knob counterclockwise
to the PILOT position. Press in control knob
for five (5) seconds (see Figure 27).
Note: You may be running this heater for
the first time after hooking up to gas sup-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
6. With thermostat control knob pressed in,
press and release ignitor button. This will
light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, contact a
qualified service person or gas supplier
for repairs. Until repairs are made, light
pilot with match. To light pilot with match,
see Manual Lighting Procedure.
7. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob.
• If control knob does not pop out when
released, contact a qualified service
person or gas supplier for repairs.
Note: If pilot goes out, repeat steps 3
through 7. This heater has a safety inter-
lock system. Wait one minute for system
to reset before lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The front burner
should light. Set control knob to any heat
level between HI and LO.
Ignitor Button
Control Knob
Models: CSG3924NT, CSG3924PT,
VRL24NT, VRL24PT, VRL30NT and VRL30PT
Figure 27 - Control Knob(s) and Ignitor
Button Locations
Ignitor Electrode
Thermocouple
Figure 28 - Pilot
(Propane/LP)
110021-01S
OPERATION
Rear Burner
Control Knob
Ignitor Electrode
Thermocouple
Pilot
Burner
Figure 29 - Pilot
(Natural)
www.desatech.com
Continued
9. To light the rear yellow flame burner, push
in and turn rear burner control knob coun-
terclockwise
10. To leave pilot lit and shut off burners only,
turn control knob clockwise
PILOT position then rear burner control
knob clockwise
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
CAUTION: Do not try to adjust
heating level of rear burner. Rear
burner control knob should be in ON
or OFF positions only. Do not oper-
ate with rear burner control knob
between ON or OFF positions.
1. Turn control knob clockwise
OFF position.
2. Turn rear burner control knob clockwise
3. Close equipment shutoff valve (see Figure
16, page 17).

THERMOSTAT CONTROL

The thermostat control knob can be set to any
comfort level between HI and LO. The thermostat
will gradually modulate the heat output and flame
height from higher to lower settings or pilot, in
order to maintain the comfort level you select. The
ideal comfort setting will vary by household de-
pending upon the amount of space to be heated,
the output of the central heating system, etc.
Note: Selecting the HI setting with the control
knob will cause the burner to remain fully on,
without modulating down in most cases.
MANUAL LIGHTING
1. Follow steps 1 through 5 under Lighting
Instructions, page 20.
2. Press control knob and light pilot with match.
3. Keep control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release control knob. Now follow steps 8
and 9 under Lighting Instructions.
to the ON position.
to OFF position.
TO TURN OFF GAS
TO APPLIANCE
to the OFF position.
OPERATION
PROCEDURE
to
to the
21