We also recommend that you keep the burner
tube and pilot assembly clean and free of dust and
dirt. To clean these parts we recommend using
compressed air no greater than 30 PSI. Your local
computer store, hardware store or home center
may carry compressed air in a can. If using com-
pressed air in a can, please follow the directions
on the can. If you don't follow directions on the
can, you could damage the pilot assembly.
1. Shut off unit, including pilot. Allow unit to
cool for at least thirty minutes.
2. Inspect burner, pilot for dust and dirt.
3. Blow air through the ports/slots and holes
in the burner.
4. Never insert objects into the pilot tube.
Clean the pilot assembly also. A yellow tip on
the pilot flame indicates dust and dirt in the
pilot assembly. There is a small pilot air inlet
about 2" from where the pilot flame comes out
HDR18NT
• Natural Gas
• 6,600/12,000/18,000 Btu/hrition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
HDR30NT
• Natural Gas
• 6,600/18,000/30,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
GWRN18B, GWRN18TB, VN18B,
VN18TB
• 6,600/12,000/18,000 Btu/hr (VN18B is variable)
• Natural Gas Only
• Electronic Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
GWRN30B, GWRN30TB, VN30B,
VN30TB
• 6,600/18,000/30,000 Btu/hr (VN30B is variable)
• Natural Gas Only
• Electronic Ignition
• Pressure Regulator Setting: 6" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 10.5" W.C., Minimum - 7" W.C.
* For purposes of input adjustment.
18
CLEANING AND MAINTENANCE

SPECIFICATIONS

www.desatech.com
Continued
of the pilot assembly (see Figure 30). With
the unit off, lightly blow air through the air
inlet. You may blow through a drinking straw
if compressed air is not available.
Figure 30 - Pilot Air Inlet
CABINET
Air Passageways
Use pressurized air to clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.
HDR16PT
• Propane/LP Gas
• 6,000/12,000/16,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
HDR26PT
• Propane/LP Gas
• 6,000/16,000/26,000 Btu/hr
• Piezo Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWRP16B, GWRP16TB, VP16B,
VP16TB
• 6,000/11,000/16,000 Btu/hr (VP16B is variable)
• Propane/LP Gas Only
• Electronic Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWRP26B, GWRP26TB, VP26B,
VP26TB
• 6,000/16,000/26,000 Btu/hr (VP26B is variable)
• Propane/LP Gas Only
• Electronic Ignition
• Pressure Regulator Setting: 8" W.C.
• Inlet Gas Pressure* (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
* For purposes of input adjustment.
Pilot Assembly
Pilot Air Inlet
124011-01B