AKR-100 Full Manual V.1.5
Miniature DVR
AKR-100
User's Manual
The contents of the manual can be modified without prior notice to customers
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AKR-100 and is the answer not in the manual?

Questions and answers

Summary of Contents for Seorim Technology AKR-100

  • Page 1 AKR-100 Full Manual V.1.5 Miniature DVR AKR-100 User’s Manual ※ The contents of the manual can be modified without prior notice to customers...
  • Page 2 8. Handle AKR-100 carefully to avoid damaging the product. If you accidentally drop your AKR-100 on any hard surface, it may cause a malfunction. If the AKR-100 doesn’t work properly due to physical damage, contact an authorized dealer for repair or exchange.
  • Page 3: Table Of Contents

    REMOTE CONTROL PANEL Chapter 4: Getting Started OVERVIEW OF SET UP PROCEDURES Chapter 5: Hardware Installation SD MEMORY INSTALLATION CONNECTING AKR-100 TO YOUR TV SET OR MONITOR ALARM INSTALLATION Chapter 6: AKR-100 Menu 1. ACCESS TO OSD MENU 2. MAIN MENU 3.
  • Page 4 AKR-100 Full Manual V.1.5 7.1 PASSWORD CHANGE 7.2 TIME SET 7.3 BRIGHTNESS 7.4 AUDIO 7.5 VIDEO 7.6 MEMORY SYNC 8. DEFAULT Appendix: TECHNICAL SPECIFICATIONS RECORDING TIME TABLE RECORDING...
  • Page 5: Chapter 1: Packing Contents

    AKR-100 Full Manual V.1.5 Chapter 1: Packing Contents ▶ Contents in the package AKR-100 Main Unit Remote Control AV-IN / AV-OUT Connector Terminal Block 12V Power Supply Installation CD Quick Guide SD Card (Option) USB SD Reader (Option)
  • Page 6: Chapter 2: Getting To Know Your Akr-100

    AKR-100, refer to Chapter 6, AKR-100 MENU. Sensor-in / Alarm-out The sensor terminal block is used to connect a sensor such as PIR to the AKR-100. If you add motion sensor devices to your AKR-100, the video recording can be triggered by event.
  • Page 7 Power LED This light indicates the AKR-100is powered up. Remote control Receiver When controlling AKR-100 by remote control, be sure to point at the receiver. Reset Press the reset button if you want to return setting values to the default.
  • Page 8: Chapter 3: Remote Control

    AKR-100 Full Manual V.1.5 Chapter 3: Remote control REC: The button to start recording or stop recording MENU: The button to enter ‘MENU’ mode. UP/ DOWN: The buttons to choose a menu field and change a value. FF: The button to play recorded video forward.
  • Page 9: Chapter 4: Getting Started

    AKR-100 does not record nor play the recorded stream. It just shows the current images from camera connected to AKR-100. ● The default values of AKR-100 for recording are set up at 30 frames per second with normal video quality. If you use 1GB SD Memory, AKR-100 can record approximately for 2 hours in a row.
  • Page 10: Chapter 5: Hardware Installation

    SD card into the HDD of our PC. You can also check each recorded file through AKR Player. ※ Seorim Technology recommends SanDisk or Transcend SD, which has been proved to be compatible with AKR-100. Seorim Technology does not guarantee compatibility with other makers’.
  • Page 11: Alarm Installation

    Note: The RCA cable required for this connection does not come packaged with the AKR-100. ALARM INSTALLATION The AKR-100 has an internal switch for sounding an alarm. When a sensor is triggered, the alarm is activated as well. There are two steps to install an alarm.
  • Page 12 AKR-100 Full Manual V.1.5 Note: Contact an authorized dealer for information about buying the appropriate alarm device for your needs and for information concerning proper installation procedures.
  • Page 13: Chapter 6: Akr-100 Menu

    AKR-100 * * * * Press ‘MENU’ button on remote control to access to AKR-100 OSD menu. Please refer to ‘Chapter 3: Remote control’ about how to use remote control buttons. Password is ‘0000’ as default. The password can be changed on ‘[SUB MENU] [PASSWORD CHANGE]’.
  • Page 14: Record Mode

    AKR-100 Full Manual V.1.5 In the main menu, the ‘indicator ‘■’ will be shown on the left of each menu. Press ‘UP/DOWN’ button on remote control to select a desired menu. After placing ‘■’ on the desired menu and press ‘ENTER’ button to enter the menu.
  • Page 15: Video Quality

    AKR-100 Full Manual V.1.5 4. VIDEO QUALITY 4. VIDEO QUALITY 4.1 LEVEL (HIGH / NORMAL / LOW): Select desired video level from ‘LOW’ to ‘HIGH’. Compression Bitrate for HIGH: 1.2Mbps Compression Bitrate for Normal: 750Kbps Compression Bitrate for Low: 500Kbps 4.2 POST RECORDING TIME: Post recording time means the time between one event and the next one.
  • Page 16: Event Mode

    5.1.1 ALARM INPUT (ON / OFF): Select ‘ON’ if you want to use alarm input device. 5.1.2 TYPE: Select alarm input type between ‘NO’ and ‘NC’ NC: NORMAL CLOSE NO: NORMAL OPEN Note: In NORMAL-CLOSE mode, if an intruder cuts the cable line that connects the sensor to the AKR-100,...
  • Page 17 In NORMAL-OPEN mode, if an intruder cuts the cable line that connects the sensor to the AKR-100, the sensor recording will not start at. 5.1.3 ALARM OUTPUT (ON / OFF): Select ‘ON’ if you want to use alarm output device 5.1.4 TYPE: Select alarm output type between ‘NO’...
  • Page 18: Search

    AKR-100 Full Manual V.1.5 5.3 SCHEDULE SETUP MON to FRI 00:00 ~ 09:00 MON to FRI 18:00 ~ 23:59 MON to FRI 00:00 ~ 09:00 The recording time can be scheduled on this menu. Up to 4 schedules can be set up.
  • Page 19: Sub Menu

    AKR-100 Full Manual V.1.5 6.1.2 SEARCH MODE – EVENT: When you select ‘EVENT (or BOTH) on SEARCH MODE’, additional search conditions opens; ALARM / EMERG (Emergency) / MOTION You can select 2 or more conditions simultaneously (ALARM / EMERG / MOTION).
  • Page 20 AKR-100 Full Manual V.1.5 7.1 PASSWORD CHANGE The Factory Default Password is 0000. To enter this number, press the UP/DOWN button on the remote control. Once you input the your current password, set a new six digit password using the buttons UP, REW, DOWN, FF on the remote control.
  • Page 21 AKR-100 Full Manual V.1.5 7.3 BRIGHTNESS Select brightness value among low, medium and high. 7.4 AUDIO Audio function can be turned OFF or ON in the menu. Note: When you do audio recording, you have to set the RECORD FRAMERATE over 4. If you set it under...
  • Page 22 7.6 MEMORY SYNC The index file is automatically generated and stored in SD card inserted into AKR-100. If the index file does not match to the files actually stored in the SD card, users can synchronize the index file list and actual file list.
  • Page 23 AKR-100 Full Manual V.1.5 8. DEFAULT To reset AKR-100 settings back to the factory default, select ‘YES’ and enter it. After resetting, the password will return to the default value (0000) as well as all settings of AKR-100 on the menu.
  • Page 24 AKR-100 Full Manual V.1.5 APPENDEX SPECIFICATION ITEM DESCRIPTION VIDEO Video Input Format PAL / NTSC auto detection function Operating system RTOS in firmware Video Input Channels 1CH Composite video Video Output Channels 1CH Composite video Input Level 1.0Vp-p +/-10% Composite, 75 Ohm Unbalanced Main TV Output 1 1.0Vp-p Composite, 75 Ohm Unbalanced...
  • Page 25 AKR-100 Full Manual V.1.5 RECORDING CONDITIONS Based on 1GB of storage with the installation of 1 camera Approximate Recording Time Table Mode HIGH(30frame) NORMAL(30frame) LOW(30frame) REMARK Video 1200Kbps 700Kbps 500Kbps Quality Recording 7,054 Sec 8,830 Sec 9,492 Sec (Actual storage space...
  • Page 26 AKR-100 Full Manual V.1.5 Seorim Technology Co., Ltd #1001, daerung technotown vi, 493-6, gasan-dong, kumchun, seoul, korea, 153-803 Tel: +82-2-2108-5860 Fax: +82-2-2108-5869 E-mail: sales@seorimtech.com http://www.seorimtech.com...

Table of Contents