Electrical Fuse Size/Circuit Ampacity - Manitowoc J250 Service Manual

J-series
Hide thumbs Also See for J250:
Table of Contents

Advertisement

Section 2

Electrical Fuse Size/Circuit Ampacity

All electrical work, including wire routing and
grounding, must conform to local, state and
national electrical codes.
VOLTAGE
The maximum allowable voltage variation is +/- 10%
of the rated voltage, at start-up (when the electrical
load is the highest).
FUSE/CIRCUIT BREAKER
A separate fuse/circuit breaker must be provided for
each ice machine. Circuit breakers must be H.A.C.R.
rated. (H.A.C.R. rating does not apply in Canada.)
J250 Ice Machines with Power Cord (Cord is 6' long, with NEMA 5-15P plug configuration.)
Ice
Voltage, Phase,
Machine
J250
J250 Ice Machines Requiring Direct Wiring
Ice
Voltage, Phase,
Machine
J250
208-230/1/60
WARNING
Maximum
Cycle
Fuse/Circuit
Breaker
115/1/60
Maximum
Cycle
Fuse/Circuit
Breaker
230/1/50
MINIMUM CIRCUIT AMPACITY
The minimum circuit ampacity is used to help select
the wire size of the electrical supply. (It is NOT the
ice machine's running amp load.)
The wire size, or gauge, is also dependent upon the
location, materials used, length of run, etc., and
therefore must be determined by a qualified
electrician.
Air-Cooled
Total
Amps
15
8.8
Air-Cooled
Minimum
Circuit
Amps
15
4.8
15
4.8
Installation References
Water-Cooled
Maximum
Fuse/Circuit
Breaker
15
Water-Cooled
Maximum
Fuse/Circuit
Breaker
15
15
Total
Amps
8.0
Minimum
Circuit
Amps
4.2
4.2
2-7