CABINET INSTALLATION
Note: See previous page if wall mount installation is
preferred.
Note: Distances on page 7.
4. Find the centerline of the cabinet bottom. Draw a
line along this centerline from rear to front of the
cabinet.
5. Draw two lines, one at a K distance from the wall,
the other one at a Z distance from the previous line.
Mark 4 points – two along each line at a distance of
half W from the center line – to determine the screw
locations.
6. Fit 4 screws on cabinet bottom. Do not tighten
completely. Leave a space of about ½" from cabinet
bottom surface and screw heads.
7. Run 8" duct, long enough to reach the transition
once the hood has been installed plus 1½" inch to
connect ductwork.
8. Remove 1 of 2 knockouts and install ½" conduit
connector in j-box.
9. Mount the hood on screws through side slots
provided on hood top. Tighten the four screws.
Note: If possible fix the hood on the wall at
4 additional points (2 on upper side, 2 on lower side).
10. From the inside of the cabinet attach the transition
on upper outlet (vertical discharge - see also
"Assembly of the 8" Transition" on previous pages).
Hook for Wall Installation
12 / "
7½"
Figure 6b
1 Ft = 0.3 m
1" = 2.5 cm
Installation Instructions
CL
Screw for
Cabinet
3
25 / "
16
Bottom
Installation
5
12 / "
5
8
8
Adjusting
CL
Screw
Bottom of
the Hood
FOR BOTH INSTALLATION METHODS
11. Wiring the hood
WARNING!
Electrical Shock Hazard: Turn off power at the service
panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED WITH AN ELECTRICAL
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT AGAINST ELECTRIC
SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR
HOME ELECTRICAL SYSTEM, AND MUST UNDER
NO CIRCUMSTANCES BE CUT OR REMOVED.
Failure to do so can result in death or electrical shock.
• Remove the j-box cover as shown in Figure 7.
• If not already done, install ½" conduit connector
in j-box.
• Run black, white, and green wires (#14 AWG)
according to the National Electrical Code or CSA
Standards and local codes and ordinances.
• Connect black, white, and green wires from power
supply to black, white, and green/yellow wires in
j-box respectively.
• Close j-box cover.
From Control
Panel
12. Final installation steps
• Install grease filters, lamps and drip trays as
described in the Care & Use section of this
manual.
Note: Lamps are not supplied; use ONLY 120 Volt,
50 Watt (maximum) 50° halogen light made for a
GU10 base, suitable for use in open luminaries.
• Turn power on at service panel.
• Check operation of the hood.
1 3
Power Supply Conduit
Figure 7