PlannInG InSTallaTIOn

Carefully check the range hood for damage and for missing parts
prior to installation . If there is any damage or if you are missing parts,
do not proceed with the installation . Report damage and missing
parts immediately . Do not dispose of packaging before you are
satisfied with your new range hood .
1 . Before installation, measure all distances to ensure the proper
position of the range hood (A) .
□ The distance (1) from the cooking surface to the range hood
must be at least 457 mm (18 in .) . For the best performance,
do not install the range hood more than 762 mm (30 in .)
above the cooking surface .
□ The distance (2) from the floor to the cooking surface should
be approximately 914 mm (36 in .) .
□ The size of the range hood installation location must be at
least 757 mm (29 .8 in .) wide (3), 457 mm (18 in .) deep (4)
and 178 mm (7 in .) high (5) to accommodate the range hood .
2 . If the bottom of the cabinet (6) above the location where the range
hood is to be installed is recessed, attach appropriately sized wood
filler strips (7) on each side using wood screws .
3 . Screws are provided to secure the range hood to most types of
cabinets, but consult a qualified installer to verify that the supplied
screws are suitable for your cabinets .
4 . Put a thick, protective covering over your counter, cooktop, or
range to protect it from damage and dirt during installation .
Remove any hazardous objects around the area .
5 . Determine if your existing venting system is top venting or back
venting, and ensure that the openings in the cabinet or wall for the
damper and for power access are in appropriate locations and are
of appropriate sizes, as decribed below .
If this is a new installation, choose the venting method that suits
your needs . Cut out openings for the damper and for power access
in the cabinet bottom or exterior wall, depending on the direction of
venting chosen .
For top venting:
□ Cut one square hole (8) with a width of 260 mm (10 .24 in .)
and a depth of 100 mm (3 .937 in .) in the bottom of the
cabinet . Center the hole on the center line (12) of the cabinet
with its back edge 28 mm (1 .102 in .) from the back wall .
□ Cut one circular hole (9) of a diameter of 32 mm (1 .26 in .) .
Center the hole 285 mm (11 .22 in .) from the center line
(12) of the cabinet and 39 mm (1 .54 in .) from the back
wall .
WARNING: Always wear safety goggles and gloves
during installation .
NOTICE: Installation of this product requires
two or more people .
4
6
7
7
Please contact 1-800-394-1720 for further assistance .
7
7
3
Top Venting Option
12
8
9
Back Venting Option
12
11
10
HOMEDEPOT .COM
5
A
1
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents